Do you have a question about the Oakton PC 700 and is the answer not in the manual?
pH Resolution | 0.01 pH |
---|---|
pH Accuracy | ±0.01 pH |
mV Resolution | 1 mV |
Temperature Resolution | 0.1 °C |
Temperature Accuracy | ±0.5 °C |
Conductivity Accuracy | ±1% full scale |
TDS Accuracy | ±1% full scale |
Salinity Accuracy | ±1% full scale |
Display | LCD with backlight |
mV Range | ±1999 mV |
mV Accuracy | ±0.2 mV |
Temperature Range | -5.0 to 105.0°C |
Conductivity Resolution | 0.1 μS/cm; 1 μS/cm; 0.01 mS/cm; 0.1 mS/cm |
TDS Resolution | 0.1 ppm; 1 ppm; 0.01 ppt; 0.1 ppt |
Salinity Range | 0 to 80 ppt |
Salinity Resolution | 0.1 ppt |
Temperature Compensation | Automatic |
Calibration | Up to 5 points |
Power Supply | 4 x 1.5V AAA batteries |
Explains the function of each button on the meter's keypad.
Describes the meaning of various symbols and indicators displayed on the meter's LCD screen.
Details the different ports and connectors on the meter for electrodes and power.
Guides on performing pH calibration using buffer solutions and the procedure.
Explains how to adjust the millivolt offset for ORP/Redox measurements for comparability.
Describes the capabilities for automatic and manual calibration for conductivity and TDS.
Details the options for single-point and multi-point calibration strategies.
Provides general advice and best practices for accurate meter calibration.
Step-by-step instructions for performing automatic conductivity calibration.
Step-by-step instructions for performing manual conductivity and TDS calibration.
Explains the procedure for calibrating the meter's temperature measurement.
Instructions on how to properly take conductivity and TDS measurements.
Describes how the meter automatically or manually selects measurement ranges.
Accesses stored calibration points for viewing.
Displays electrode information like mV offset and slope.
Entry point for various meter configuration settings.
Configures the ready and auto-hold stability indicators.
Selects the temperature unit display between Celsius and Fahrenheit.
Configures pH buffer groups and the number of calibration points.
Enables or disables automatic temperature compensation for Con/TDS.
Sets the TDS conversion factor for conductivity measurements.
Adjusts the temperature coefficient for conductivity compensation.
Sets the normalization temperature for conductivity compensation.
Enables or disables automatic conductivity calibration.
Selects between single-point and multi-point calibration for Con/TDS.
Sets the cell constant for conductivity measurements.
Resets meter settings to factory defaults or just calibration.
Clears all stored data from the meter's memory.