OEG Heizungs- und Solarumwälzpumpen
D
Circulateurs de chauffage et solaires OEG
FR
OEG Heating and solar circulation pump
GB
Abb. ähnlich, kann
typbedingt abweichen
Fig. similar, can differ
depending on the type
Illustration similaire,
peut différer selon le type
Verglijkbare afbeelding, kan
afwijken afhankelijk van het model
• Mit neuer
Sockeltechnologie!
• With new base
technology!
• Avec nouvelle
technologie de socle!
• Met nieuwe
sokkeltechnologie!
OEG Verwarmings- en Solar circulatiepompen
NL

Table of Contents

Questions and Answers

  • S
    Sara MedinaAug 22, 2025
    Why is my OEG Water Pump making failure noises?
    • N
      Natalie JenkinsAug 22, 2025
      If you're hearing unusual noises from your OEG Water Pump, it could be due to several reasons. Air might be trapped in the system or the motor pump; try venting the system to remove any trapped air. Alternatively, the flow rate might be too high, in which case you should reduce the inlet pressure of the pump and adapt the program. Low inlet pressure or insufficient head can also cause noise; increase the inlet pressure and check the expansion vessel. Finally, the speed might be too low; adjust the signal PWM or PWM inverted at the controller.
  • M
    Monica Blankenship DDSNov 6, 2025
    What to do if my OEG 512200058 Water Pump does not start?
    • N
      nbooneNov 6, 2025
      If your OEG Water Pump doesn't start, several issues could be the cause. First, a fuse might have tripped, in which case you should replace it. Alternatively, the RCCB might have tripped; check the insulation and try switching the RCCB on again. It's also possible that the motor is defective, requiring a pump replacement. Ensure that the power supply is within the defined range, as high or low voltage can prevent the pump from starting. Other potential causes include excessive current (indicating a defective board or motor, also requiring pump replacement), lack of medium (fill the system and check the ball valves), phase failure (check the voltage supply and board), pump locks (check the rotor for unobstructed movement), or incorrect resistance values/motor current consumption (again, req...

Summary

Installation

General Installation Guidelines

General installation guidelines, including flow direction, seals, and motor shaft orientation.

Terminal Box Positioning

Illustrates correct and incorrect orientations for the pump's terminal box.

Rotating the Terminal Box

Step-by-step instructions for rotating the terminal box by 90 degrees.

Pump Housing Thermal Insulation

Guidance on insulating the pump housing and pipeline, and what not to insulate.

Electrical Installation

Commissioning

Pre-Start Procedures

Pre-operation checks including system filling and inlet pressure.

Pump Venting Procedures

Instructions on the pump's self-venting feature and manual venting process.

Troubleshooting

Pump Does Not Start Issues

Troubleshooting guide for pump start-up failures, including error codes and remedies.

Pump Noise Issues

Diagnosing and resolving common noise issues encountered with the pump.

Insufficient Head Problems

Troubleshooting steps for when the pump does not deliver sufficient head.

Low Pump Speed Issues

Addressing issues where the pump operates at a speed lower than expected.

OEG 512200058 Specifications

General IconGeneral
BrandOEG
Model512200058
CategoryWater Pump
LanguageEnglish