88 Appendix C: Priner Commands
Print Industrial Bar Code
Data
Print Postnet Bar Code
Data
Print Features
Utility / LQ Selection
Select LQ Typeface
Select font by pitch and
point
ASCII: ESC DLE B m n [data]
Dec: 27 16 66 m n [data]
Hex: 1B 10 42 m n [data]
ASCII: ESC DLE C n [data]
Dec: 27 16 67 n [data]
Hex: 1B 10 43 n [data]
ASCII: ESC x n
Dec: 27 120 n
Hex: 1B 78
ASCII: ESC k n
Dec: 27 107 n
Hex: 1B 6B n
ASCII: ESC X m n
1
n
2
Dec: 27 88 m n
1
n
2
Hex: 1B 58 m n
1
n
2
Epson
Function
Commands
(ASCII, Decimal, Hexadecimal)
n
3
, n
4
set vertical length of bars: normal
value is ([n
3
x 10] + n
4
) (
15
/
180
-inch)
n
5
sets width of modules or black bars,
depending on style engaged.
n
6
sets spacing
n
7
sets ratio of wide element to narrow
element
n
8
: Specifies whether or not characters
are to be attached
n
8
=0: characters not attached
n
8
=1 or more: LQ characters attached
Prints bar code data.
m=amount of data (in bytes) to follow n
specifies Code 128 mode (when Code
128 is selected) as follows: n=65: Set A
n=66: Set B
n=67: Set C
n=amount of data (in bytes) to follow:
n=1 to 20
Data consists of single-digit numbers
(0 to 9).
n=0: Utility printing
n=1: NLQ printing
n=0: Roman
n=1: Swiss
n=2: Courier
n=3: Prestige
n=7: Orator
n=122: Swiss Bold
n=124: Gothic
n=126: MENU setting
Selects Multipoint (scalable font) mode.
Printable font is selected by character
pitch and point
Character pitch
m=0: unchanged
m=1: Proportional
Notes