Appendix A Centronics Parallel Interface
Oki Data CONFIDENTIAL
44983601TH Rev.1
AppendixA-7/
ACKWIDTH
NARROW *
Pressthe"MENU "key.
ACK/BUSYTIMING
ACKINBUSY *
Pressthe"MENU
"key.
I-PRIME
DISABLE *
Pressthe"MENU "key.
OFFLINERECEIVE
DISABLE *
Pressthe"Online"key.
Online Thesettingiscompleted.
Items OutputorderofBUSYsignaland
ACKsignalatcompatiblereceiving
Display Function
ACKINBUSY BUSY=LOWisattheposteriorborderofACKpulse
ACKWHILEBUSY BUSY=LOWisatthecenterofACKpulse
FactoryDefault:ACKINBUSY
Items I-PRIME
Display Function
Disable I-PRIMEsignalisignored.
3microseconds EnableattheI-PRIMEsignalof3μs
50microseconds EnableattheI-PRIMEsignalof50μs
FactoryDefault:3Microseconds(B401/B411)
Disable(B431series)
Items ACKwidthatcompatiblereceiving
Display Function
Narrow 0.5μs
Normal 1.0μs
Wide 3.0μs
DefaultSetting:Narrow
Items Enable/DisableofOfineReceiving
Display Function
Disable Disable
Enable Enable
I/Fsignaldoesnotchangeandstill
keepinsignalreceivablestatus
eventhealarmsounds.
FactoryDefault:Disable
*ItisdisplayedonlywhenPSEisinstalled.