4. ADJUSTMENT
Oki Data CONFIDENTIAL
44983601TH Rev.1
4-20 /
4. Whilethemessage"PRINTEXECUTE"thatissetbytheoperationspeciedinstep2isbeingdisplayed,press
the[OK]keyandthetestprintisexecutedwiththesettingvaluethathasbeensetbysteps2and3.
Pressingthe[CANCEL]keystopsthetestprint.
Ifanyalarmthatisshowninthefollowingdetailscolumnisissuedatstartupoftestprintorwhiletestprintis
inprogress,thetestprintisinterrupted.(Forerrordetails,refertosection6.5.1LCDStatusMessage/Trouble
Table.However,thecommenttobedisplayedisdifferentinthecaseofthePUtestprint.)
Panel display Details
PAPEREND
SELECTEDTRAY
Nopaper
SELECTEDTRAYIS
NOTINSTALLED
Selected tray is not installed.
INSTALLCASSETTETRAY
OPEN
Cassette removal
Printpattern(ItcannotbeusedforcheckingPQ.)
0 to 15....... White paper print
• Duringprinting,thefollowingmessagesaredisplayed.
P=***
P : Numberoftestprintcopies(unit:copies)
• Displaysareswitchedbypressingthe[MENU
]
key.
T=*** U=***[###]
H=***%
U : ***=Upperheatertemperaturemeasurementvalue[unit: ]
 [***]=Printexecutiontargettemperature[unit:
]
T : Environment temperature measurement value [unit:
]
H : Environment humidity measurement value [unit: % ]
• Displaysareswitchedbypressingthe[MENU
]
key.
KTR=*.**
KTRindicatethetransfervoltagesettingvalue.(unit:KV)
• Displaysareswitchedbypressingthe[MENU
]
key.
KR=*.**
KR :BLACKtransferrollerresistancevalue[unit:uA]