P=*** T=*** U=*** [###]
H=***% L=***[###]
KTR=*.**KV YTR=*.**KV
MTR=*.**KV CTR=*.**KV
KR=*.**uA YR=*.**uA
MR=*.**uA CR=*.**uA
The following message appears when printing.
P: Test Print Sheets (Unit: number of sheets)
U: Upper-side Heater temperature Measurement Value[Setting] (Unit: °C)
L: Lower-Side Heater temperature Measurement Value[Setting] (Unit: °C)
T: Environmental Temperature Measurement Value (Unit: %)
H: Environmental Humidity Measurement Value (Unit: %)
Press [MENU+] key to switch the display.
YTR, MTR, CTR and KTR are image transfer voltage settings of each color. (Unit: KV)
Press [MENU+] key to switch the display.
YR, MR, CR, and KR represent the electric current (uA) of the transfer roller for each color,
respectively.
Press [MENU+] key to switch the display.
THICK: Detected medium thickness (μm)
TEMP: Fusing temperature (˚C)
REGIST: Constant speed of resist motor (hexadecimal)
EXIT: Constant speed of fuser motor (hexadecimal)
5. Accordingly repeat Steps 2 to 4.
6. Press the [BACK] key to end the test. (Returns to state 1)
THICK= *** TEMP=***
REGIST=**** EXIT=****
Troubleshooting Guide Page 22

Other manuals for Oki C930

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oki C930 and is the answer not in the manual?

Oki C930 Specifications

General IconGeneral
BrandOki
ModelC930
CategoryPrinter
LanguageEnglish

Related product manuals