Page #6 background imageLoading...
Page #6 background image
6
Specifications
For additional specifications, see the on-line User's Guide.
Electrical
Voltage
120 (110 to 127) VAC; 60 Hz, ±2Hz
230 (220 to 240) VAC; 50 Hz, ±2Hz
Power
Standby: 1300 W max.; average 200 W
Operating: 1500 W max.; average 750 W
Power Cord*: 15-amp, shielded
*Caution!
Be sure to use the power cord supplied with the
printer. Use of a power cord not supplied with the
printer, or use of an extension cord, may result in
overheating and could be a safety hazard.
Environmental
Temperature
Operating: 50 to 89.6°F (10 to 32°C)
Max. Color Print Quality: 62.6 to 80.6°F (17 to 27°C)
Power Off: 32 to 110°F (0 to 43°C)
Storage (1 year maximum): -14 to 110°F (-10 to 43°C)
Relative Humidity
Operating: 20 to 80% RH
Max. Color Print Quality: 50 to 70% RH
Power Off: 10 to 90% RH
Storage: 10 to 90% RH