EasyManua.ls Logo

Oki MB441 - Page 100

Oki MB441
182 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of the Device Setting Menu Items
- 100 -
Management
Item
Factory
Default
Description
Default Mode Copy Sets the default mode of the machine.
Opera-
tion
Clear
Operation Timeout 3 Sets time of automatic reset. Available
range: 1 to 10 minutes.
Clear After Job OFF Sets whether to reset after any job is
completed.
Sound
Control
Key Touch Tone Volume Middle Sets the volume of the key-touch tone.
FAX Buzzer Volume Middle Sets the volume for transmission complete
acknowledgment.
Local-
Inter-
face
*1
USB Menu Soft Reset Disable Sets whether to enable the soft reset
command.
Speed 480 Mbps Selects the maximum transfer speed of
USB interface.
USB PS-Protocol RAW Selects a USB PS-protocol.
Offline Receive Disable Sets whether to receive data in offline
state or in recoverable error state.
Serial Number Enable Sets whether to use a USB serial number.
System
Setup
Access Control Disable Sets access control.
User Authentication Method Local Display condition: [Access Control] is set
to [User] or [Password].
Unit of Measure millimeter Selects a displayed unit (millimeter / inch)
of measure.
Date Format dd/mm/yyyy
Allow All Reports To Print Disable Sets whether to allow printing reports with
personal information.
Near Life LED Enable Sets whether to light an LED when a near
life warning occurs.
Near Life Status Enable Sets whether a message is displayed when
a near life warning occurs.
Address Information Lock Time Out 3 minutes Sets time until a lock is released by the
machine when address book, telephone
book, or profile is kept locked by the utili-
ties. Available range: 1 to 10 minutes.
USB Memory Interface Enable When [Disable] is set. the scan to USB
and the print from USB memory functions
cannot be used.
Panel Contrast 0 Sets the LCD panel contrast. Available
range:
±10 (1 increments).
Power
Save
Power Save Time 1 minute Sets time to enter the power save mode.
Sleep Time 30 minutes Sets time to enter the sleep mode.
Auto Power Off Time 4 hours Sets time interval to turn off the
machine's power automatically.

Table of Contents

Other manuals for Oki MB441

Related product manuals