6.2.7. dLoA.
Updating data on repeater keyboards using the master keyboard.
This programming operation is used to transfer the programmed rooms from the
central keyboard(master) to the repeaters keyboards. It is used only when we have
repeater keyboards connected to the system.
Insert the technical code (1111) and use the FAULT EVENTS to scroll to the indication
S-UP, press the ENTER key and using the arrow keys scroll to the indication dLoA,
then press the ENTER key and the programmed rooms will be transferred from the
central keyboard (master)to the repeater keyboards. The duration of this process is a
few seconds and the Display shows the programs in sequence. (e.g.P1, P2, P3,
P4....P240).
At the end of the process press successively the ESC key so as to exit the
programming procedure.
6.2.8. r-AL.
Clearing and resetting the keyboard to default conditions.
This programming operation resets all the names which have been programmed for
every room and returns these values to their default settings.
Insert the technical code (1111) and using the FAULT EVENTS key scroll to the
indication S-UP, press the ENTER key and using the arrow key scroll to the r-AL,
then press the ENTER key, the keyboard resets the memory and returns the default
programming values. The duration of the process is a few seconds and the Display
shows the programs in sequence (e.g.1, 2, 3, 4...P40).
At the end of the process press successively the ESC key so as to exit the
programming procedure.