5. HOW TO MAINTAIN, CHECK AND SERVICE BURNER.
1) CHECK OF BURNER.
check the followings prior to burner operation.
after checking the water level of boiler, pressure and fuel feed rate, open the
valve between tank and oil pump.
check whether the working voltage and fuel meet the burner specification.
discharge air from the fuel pipe system.
check whether or not the burner nozzle corresponds the boiler or furnace
capacity..
maintenance of burner
clean the ignition bar if it is contaminated.
clean nozzle and nozzle adapter.
if soot is accumulated on the diffuser, burner fails to ignite.
remove the soot from the diffuser.
check and clean oil filter if required.
check and clean flame detector if required.