17 Close the air outlet plug (pink) of the air jack by rotating the plug
clockwise.
Figure 17
18 Place the air jack on the caster on the front side. At this time,
confirm that the band of air jack is not removed.
Figure 18
19 Remove the cap of the air inlet plug (white) and supply air until stand F can be removed using the pump.
CAUTION
Supply air in with the air jack in contact with the caster. Otherwise, the product may topple down.
NOTE
Remove stand F by supplying air while using the line (yellow) as a reference. If stand F is hard to remove, feed
more air with the pump.
Air outlet plug (pink)
Band
Figure 19
Air jackStand F
Pump
Air inlet plug
(white)
Air jack Line (yellow)
Figure 20