INSTRUCTIONS
EVIS EXERA III XENON LIGHT SOURCE
OLYMPUS CLV-190
Labels and Symbols 1
Important Information — Please Read Before
Use 3
Summary of the Equipment Functions 12
Chapter 1 Checking the Package Contents 15
Chapter 2 Nomenclature and Functions 17
Chapter 3 Installation and Connection 27
Chapter 4 Inspection 41
Chapter 5 Operation 65
Chapter 6 Lamp Replacement 81
Chapter 7 Reprocessing, Storage,
Disposal, and Transportation 93
Chapter 8 Troubleshooting 103
Appendix 109
USA: CAUTION: Federal law restricts this device to sale by or on the order of a physician.

Table of Contents

Other manuals for Olympus EVIS EXERA III

Questions and Answers

  • N
    Natalie WellsNov 25, 2025
    Why is the field of view too dark or bright on my Olympus EVIS EXERA III?
    • J
      Jeanette DouglasNov 25, 2025
      If the field of view and image are too dark or too bright on your Olympus Medical Equipment, consider these potential causes: * The examination lamp may be old or the emergency lamp may be active, requiring replacement of the examination lamp. * The endoscope or light guide might not be correctly connected to the output socket; ensure a secure connection. * The brightness might be unsuitable; adjust the brightness to a suitable level. * Transillumination may be activated; wait for auto return or press the transillumination button again. * The video system center and/or light source cable may be improperly connected; ensure proper connection. * The video system center may be OFF; turn it ON. * The NBI mode may be set; press the observation mode button to return to the normal ...
  • C
    Christina GonzalezAug 23, 2025
    What to do if no light is emitted from the endoscope of my Olympus EVIS EXERA III Medical Equipment?
    • T
      Tamara MartinezAug 23, 2025
      If no light is emitted from the endoscope of your Olympus Medical Equipment, ensure that the examination lamp has been ignited by pressing the lamp button. Also, check that the endoscope or light guide is securely connected to the output socket.
  • M
    Matthew YorkAug 25, 2025
    Why is my Olympus EVIS EXERA III Medical Equipment beeping?
    • B
      Brenda StevensAug 25, 2025
      If you hear a series of beeps from the Olympus Medical Equipment, it indicates that the temperature of the light source is too high. Turn the light source OFF, make sure the ventilation grills are not covered, allow the light source to cool down, and then turn it ON again.
  • B
    Benjamin ParrishAug 27, 2025
    How to fix Olympus EVIS EXERA III Medical Equipment when the examination lamp does not ignite?
    • J
      Jeffrey GriffithAug 28, 2025
      If the examination lamp on your Olympus Medical Equipment does not ignite, consider the following: * Press the lamp button to attempt ignition. * Ensure the examination lamp is installed correctly. If not, install the examination lamp. * If already installed, reinstall the examination lamp. * The examination lamp may be broken, requiring replacement with a new one. * If the examination light is ON, turn it OFF and try igniting the examination lamp again.
  • R
    Roger MitchellAug 29, 2025
    Why is NBI observation disabled on my Olympus EVIS EXERA III?
    • T
      Theresa PattersonAug 29, 2025
      If NBI observation is disabled on your Olympus Medical Equipment, it might be due to an incompatible endoscope or light source cable being connected. Ensure you connect an endoscope and light source cable that are compatible with NBI observation. Also, verify that the NBI observation mode is selected by pressing the observation mode button.
  • A
    amandabartlettSep 23, 2025
    What does it mean when the Olympus EVIS EXERA III emergency lamp indicator blinks?
    • K
      kennethjonesSep 23, 2025
      If the emergency lamp indicator is blinking on your Olympus Medical Equipment, the emergency lamp has likely blown or failed. Immediately turn the light source OFF and unplug the power cord from the wall mains outlet and the power inlet.
  • A
    alexanderluceroSep 16, 2025
    Why can't I activate the transillumination function on my Olympus EVIS EXERA III?
    • D
      Dennis Suarez IISep 16, 2025
      If the transillumination function cannot be activated on your Olympus Medical Equipment, it may be due to the endoscope not being connected to the output socket. Ensure the endoscope is securely connected. It could also be due to a light guide being connected or an incompatible endoscope being used. Connect the endoscope with the transillumination function compatibility.
  • S
    Sean ThomasSep 18, 2025
    Why can't I set the high intensity mode on my Olympus Medical Equipment?
    • B
      Briana LeonardSep 18, 2025
      If the high intensity mode cannot be set on your Olympus Medical Equipment, an incompatible endoscope or light guide might be connected to the output socket. Connect an endoscope or light guide cable with high intensity mode compatibility.
  • T
    thomas66Sep 8, 2025
    What does it mean if the Olympus EVIS EXERA III examination lamp doesn't ignite and the emergency lamp indicator lights up?
    • J
      jacksonmarySep 8, 2025
      If the examination lamp does not ignite and the emergency lamp indicator lights up on your Olympus Medical Equipment, it could be due to the examination lamp not being installed, not installed correctly, or being broken. Install or reinstall the examination lamp, or replace it with a new one.
  • J
    Justin PerkinsSep 5, 2025
    Why doesn't the brightness change on my Olympus Medical Equipment?
    • A
      acarterSep 5, 2025
      If the brightness does not change on your Olympus Medical Equipment even when the brightness buttons are pressed, the level might be set to the minimum or maximum. Adjust the brightness to an optimum level or try turning the light source OFF and then ON again.

Summary

Labels and Symbols

Important Information - Please Read Before Use

Intended Use, Applicability, and Manual Review

Covers intended use, applicability, and the importance of thoroughly reviewing the instruction manual.

Dangers, Warnings, and Cautions

Provides critical safety warnings and precautions for handling the light source.

Chapter 2 Nomenclature and Functions

2.2 Front Panel Controls and Indicators

Details the nomenclature and function of the front panel components and their indicators.

2.3 Rear and Side Panel Nomenclature

Details the nomenclature and function of the rear and side panel connectors and features.

Chapter 3 Installation and Connection

3.1 Installation and Connection Precautions

Outlines critical safety precautions before installing and connecting the equipment.

3.3 Equipment Installation Guidelines

Gives general instructions and cautions for physically installing the light source on a stable surface.

3.6 Video System Center Connection

Guides on connecting the light source to various Olympus video system centers using specified cables.

3.8 AC Mains Power Supply Connection

Provides instructions and safety warnings for connecting the light source to the power outlet.

Chapter 4 Inspection

4.1 Inspection Precautions

Lists essential safety warnings and precautions to observe before performing inspections.

4.5 Power Supply Inspection

Checks the power supply status, indicators, ventilation, and lamp cover attachment.

4.9 Brightness Adjustment Inspection

Details how to inspect brightness adjustment for both automatic and manual modes.

Chapter 5 Operation

5.1 Attention to Operation

Lists important warnings and precautions to observe during normal operation.

5.3 Turning ON Light Source and Igniting Lamp

Details the procedure for powering on the light source and igniting the examination lamp.

5.5 Brightness Adjustment

Explains how to adjust light intensity for observation in automatic and manual modes.

5.11 Turning the Light Source OFF

Provides instructions on safely powering down the entire light source unit.

Chapter 6 Lamp Replacement

6.1 Xenon Lamp Replacement Precautions

Provides warnings and instructions for safely replacing the xenon examination lamp.

Chapter 7 Reprocessing, Storage, Disposal, and Transportation

7.1 Reprocessing Procedures

Outlines the general procedures for reprocessing the light source and accessories.

7.5 Reprocessing Workflow

Describes the workflow for cleaning and disinfecting the light source and its accessories.

Chapter 8 Troubleshooting

8.1 General Troubleshooting Approach

Introduces the troubleshooting section and general advice for resolving issues.

8.2 Troubleshooting Guide

Provides a table of common irregularities, their possible causes, and solutions.

Olympus EVIS EXERA III Specifications

General IconGeneral
ModelEVIS EXERA III
CategoryMedical Equipment
TypeEndoscopy System
ManufacturerOlympus
System TypeVideo Endoscopy System
Video ProcessorCV-190
HD OutputYes
Power Requirements100-240 V AC, 50/60 Hz
Image QualityHDTV
Compatible EndoscopesEVIS EXERA III series endoscopes
Image EnhancementNBI (Narrow Band Imaging)
Light SourceXenon Lamp