O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:info@omacpompe.com SitoWeb:www.omacpompe.com
2
Rev.4 del 01/2011 O.M.A.C. s.r.l.
Chap.6 - pag.
6.2 Disassembly
With reference to chapter 3, using PPE and the tools described herein, free the pump from its fi xings, following the indications, in section 3.3 (installation),
in reverse order
ATTENTION
use the proper P.P.E.;
use the adequate tools;
follow the procedure described in section 3.3 in reverse order;
fi r st of all disassemble the any optional features present on the pump;
unscrew the suction and delivery connections from the plant;
remove the fi xing screws from the base;
extract the LDPU from its position, using hoisting equipment.
DANGER
Considering the mass of the lobe pump, the hoisting and transfer stages must only be carried out by skilled personnel and under the direct supervision
of technical personnel headed by the respective manufacturers.
using a clean cloth that does not leave any fl uff, clean the external parts accurately (both externally and the easily accessible internal parts);
WARNING
For cleaning, only use a clean cloth that does not leave any fl uff.
free the LDPU from its anchoring;
the unit is now free from its anchoring and ready to be handled, as defi ned in chapter 2 of this manual.
6.3 Storage after its use
After the disconnection and cleaning operations, put the LDPU in its original packaging, fi xing it and trying to ensure good stability.
Using appropriate hoisting means, put the packed LDPU in a dry sheltered place at room temperature.
6.4 Demolition and disposal
Following the indications of the European Community Directives in force at the time of demolition, the user must take care of the disposal of the materials
that make up the machine.
It is good practice for the user, before demolishing the lobe pump, to communicate all the data carried on the nameplates and relating to the components
that will be demolished to the relative manufacturers.
The LDPU is made with materials that are not subject to specifi c obligations for toxicity and / or harmfulness and therefore do not require particular
disposal procedures, except for the oils present (with reference to section 5.6); substances that must be disposed of in compliance with the legislative
obligations in force, as indicated in the relative safety sheet, with reference to sections 5.8, 5.9, 5.10.
WARNING
The LDPU presents some substances that must be disposed of in compliance with the legislative obligations in force.
DO NOT DISPOSE OF THESE MATERIALS IN THE ENVIRONMENT
In case of demolition, the user, in accordance with the local law regulations, must take special precautions regarding the disposal of signifi cant materials
from the environmental point of view, such as:
plastic materials of pneumatic pipes (when present)
coated electric cables (when present)
any remaining toxic or corrosive substances
Lubricant oil of the gear box.