Details the three display areas: Main, Second, and Third, with specifications for each.
Specifies the standard 9V battery type and estimated battery life of 17.5 hours.
Explains the '+' symbol displayed on the LCD when the battery voltage drops.
Provides the physical dimensions of the device: 192mm(H) x 91mm(W) x 52.5mm(D).
States the total weight of the calibrator thermometer as 320g.
Describes the device's performance during RS radiation interference tests.
Lists the included accessories such as thermocouple wires, manual, and software.
Details environmental operating and storage conditions.
Details electrical specifications including temperature scale and accuracy.
Details the resolution and accuracy for simulating thermocouple ranges.
Specifies the range, resolution, and accuracy for millivolt measurements.
Defines the temperature coefficient for accuracy specifications.
Identifies physical ports and interfaces on the top of the device.
Describes the function of the power button for turning the thermometer on/off.
Explains how to cycle through temperature scales (°C, °F, °K) using the button.
Details how to select the thermocouple type (K, J, T, etc.) using the 'type' button.
Explains how to turn the LCD backlight on/off and the auto-off feature.
Describes the automatic power-off function and how to cancel or activate it.
Explains the relative value function for comparing measurements.
Describes how to activate and deactivate the data hold mode.
Explains how to cycle through T1, T2, and SOURCE, and adjust values.
Details how to enter offset adjustment mode and set the thermocouple offset.
Explains how to enter MIN/MAX recording mode and view recorded values.
Describes the usage of the rotary knob for selection and value adjustment.
Explains how to set temperature points in PWM groups for output.
Explains how to exit group out mode.
Instructions for replacing the 9-volt battery.
Guidance on how to clean the device case and meter.
Instructions on how to uninstall the CL3515R software.
Instructions for selecting the correct COM port for device connection.
Adjust output in real time and send settings for calibration.
Automated sending of step items for calibration or testing.
Instructions for recording, exporting, and viewing measurement logs.
Configure meter settings, groups, and step items.
Details on adjusting the thermocouple offset through the software interface.
Details T1, T2, Channel Subtract, ALARM, HOLD, and Clear functions.
Procedures for submitting warranty and repair requests and inquiries.