Front Panel Controls
A. Arc Argon gas and weld current controlled by
the “Weld” switch. LED indication.
B. Purge Allows the gas line and electrode shield to
be purged of air prior to a new welding period.
C. Weld Switch Initiates a welding operation (in “arc” mode
also opens the Argon valve).
D. Argon LED Indicates when the Argon control valve is open
and gas is flowing.
E. Wait LED Glows when weld charge is building.
F. Ready LED “Ready to Weld” indication.
G. Power Rotary control of the capacitor charge voltage.
H. Level selector Selects the total capacitance available giving
the following values with LED indication.
“LO” = 0 to 6 Joules
“MED” = 0 to 28 Joules
“HI” = 0 to 64 Joules
I. Electrode Holder Holds the replacea
ble carbon electrode which
is accessible by removing the outer Argon
Shield.
J. Red socket Output socket for using the pliers supplied.
K. Black socket Output socket, this provides an additional earth.
point if required.