Rear Panel Controls
A. ON/OFF switch Power to instrument ON/OFF
B. Weld jack socket Footswitch connection
C. Argon inlet For connection to Argon supply
D. IEC power inlet module For selection of 110-120 Vac or 220-
250 Vac power supply. Factory default
setting 220-250 Vac.
Setting Up
1. Using a suitable connector fused at 5 amps, connect to mains
supply.
2. If Argon is to be utilised, couple argon hose to rear of welder.
Do not over-tighten as a good seal will be made with the nut
slightly more than finger tight.
3. Connect free end of argon hose to the argon supply via an argon
flow regulator.
4. Switch on.
5. Hold welding mode switch in “purgeposition and adjust argon
flow to 8 litres per min.
The apparatus is now ready for use.