Model
Maxi-
mum
appli-
cable
motor
ca-
paci-
ty
[kW]
 Recommended
wire size [mm2]
Inverter ground (G)
HHD mode HND mode
Allowable tempera-
ture (Note 1)
60°C 75°C 90°C
3G3M1-AB001-ECT - 0.1 2.0 2.0 2.0
- 3G3M1-AB001-ECT 0.2 2.0 2.0 2.0
3G3M1-AB002-ECT - 2.0 2.0 2.0
- 3G3M1-AB002-ECT 0.4 2.0 2.0 2.0
3G3M1-AB004-ECT - 2.0 2.0 2.0
- 3G3M1-AB004-ECT 0.55 2.0 2.0 2.0
3G3M1-AB007-ECT - 0.75 2.0 2.0 2.0
- 3G3M1-AB007-ECT 1.1 2.0 2.0 2.0
3G3M1-AB015-ECT - 1.5 2.0 2.0 2.0
- 3G3M1-AB015-ECT 2.2 2.0 2.0 2.0
3G3M1-AB022-ECT - 2.0 2.0 2.0
- 3G3M1-AB022-ECT 3 2.0 2.0 2.0
3G3M1-AB037-ECT - 3.7 3.5 3.5 3.5
Note 1: At an allowable temperature of 60°C, use 600 V IV insulated wire, at 75°C 600 V HIV insulated
wire, and at 90°C 600 V crosslinked polyethylene insulated wire.
Note 2:
When the recommended wire size is 38 mm
2
, use crimped terminal model No. 38-6 made by
J.S.T
. Mfg. Co., Ltd. or an equivalent product (*1 in table).
Note 3:
When the recommended wire size is 60mm
2
, use crimped terminal model No. 60-6 made by J.S.T.
Mfg. Co., Ltd. or an equivalent product (*2 in table).
2 Design
2-48
M1 Series EtherCAT Type User’s Manual (I670)

Table of Contents