Precautions/
Remarks
None
Event name Inverter Overheat Error Event code 08810000 hex
Meaning The inverter’s internal temperature exceeded the allowable range.
Source EtherCAT Master Function Mod-
ule
Source details Slave Detection tim-
ing
Continuously
Error attrib-
utes
Level Minor fault Recovery Error reset Log category System log
Effects User program Continues. Operation Motor stops.
Indicators EtherCAT NET RUN EtherCAT NET ERR EtherCAT LINK/ACT
--- --- ---
System-de-
fined varia-
bles
Variable Data type Name
None None None
Cause and
correction
Assumed cause Correction Prevention
(1) The inverter’s ambient tem-
perature exceeds the specified
range.
Measure the ambient tempera-
ture.
→ Lower the ambient tempera-
ture of the inverter
, for example,
by improving the ventilation in
the panel.
Examine the ambient tempera-
ture of the inverter and provide
the necessary cooling.
Attached in-
formation
None