EasyManuals Logo

Omron 3G3M1-A4007-ECT User Manual

Omron 3G3M1-A4007-ECT
808 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #240 background imageLoading...
Page #240 background image
Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit
X152
Fifth Last Alarm Info. Output Cur-
rent
0.00 to 99.99 A
0 - A
X153
Fifth Last Alarm Info. Cumulative
Ope. Time
0 to 655350 hour
0 - h
X154
Fifth last Alarm Info. Main Circuit
DC Voltage
0.0 to 1,000.0 V
0.0 - V
X158
Fifth last Alarm Info. Cumulative
Running time
0 to 655350 hour
0 - h
X159
Fifth Last Alarm Info. Running
Status
Bit15: BUSY (During function
code data writing)
Bit14: -
Bit13: -
Bit12: RL (Communications ef-
fective)
Bit11: ALM (Alarm relay)
Bit10: DEC (During decelera-
tion)
Bit9: ACC (During accelera-
tion)
Bit8: IL (During current limit-
ing)
Bit7: VL (During voltage limit-
ing)
Bit6: TL (Torque limiting)
Bit5: NUV (Main circuit DC
voltage established)
Bit4: BRK (During braking)
Bit3: INT (Inverter shut down)
Bit2: EXT (During DC braking
or during pre-exciting)
Bit1: REV (During reverse op-
eration)
Bit0: FWD (During forward op-
eration)
0
- -
4 Parameter List
4-74
M1 Series Standard Type User's Manual (I669)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron 3G3M1-A4007-ECT and is the answer not in the manual?

Omron 3G3M1-A4007-ECT Specifications

General IconGeneral
BrandOmron
Model3G3M1-A4007-ECT
CategoryInverter
LanguageEnglish

Related product manuals