Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit Page
F25 1st Stop Frequency
0.0 to 60.0 Hz
0.2
Availa-
ble
Hz
page
7-1
14
F26
Carrier Frequency
0: 0.75 kHz
1: 1 kHz
2: 2 kHz
3: 3 kHz
4: 4 kHz
5: 5 kHz
6: 6 kHz
7: 7 kHz
8: 8 kHz
9: 9 kHz
10: 10 kHz
11: 11 kHz
12: 12 kHz
13: 13 kHz
14: 14 kHz
15: 15 kHz
16: 16 kHz
2
Availa-
ble
kHz
page
7-113
F27 Motor Sound T
one
0: Level 0 (Disable)
1: Level 1
2: Level 2
3: Level 3
0
Availa-
ble
-
page
7-113
F29
Output Terminal [AO]
Mode Selection
0: Output in voltage (0 to 10
VDC)
1: Output in current (4 to
20mADC)
2: Output in current (0 to
20mADC)
3: Pulse output
0
Availa-
ble
-
page
7-46
F30
Output Terminal [AO]
Gain
0 to 300 %
100
Availa-
ble
%
page
7-46
4 Parameter List
4-81
M1 Series Standard Type User's Manual (I669)
4-2 List of Parameters by Group
4
4-2-1 Parameter F (Basic Functions)