(4) The PLC memory data cannot be maintained when the PLC model is changed. Open the PLC Memory Window
for both C200HX/HG/HE and CJ2, and copy and paste the necessary memory data.
(5) The I/O allocation of C200HX/HG/HE is partly different from that of CJ2. Refer to Appendix B. Change of unit
area allocation and modify the ladder program.
(6) The PLC settings of C200HX/HG/HE are partly different from those of CJ2. Refer to Appendix C. Change in
PLC settings and change the PLC settings.
(7) Select Compile from the Program Menu to check the program. If an error is detected, correct it.
(8) Save the program with a new project name. (Select Save As from the File Menu.)
Select the necessary PLC Memory on the C200HX/HG/HE PLC Memory Window,
and copy and paste it onto the CJ2 PLC Memory Window.