7
Serial Communications Connection Procedure
28
4
The setting items of Port2:
Protocol macro Settings are
listed as shown in the figure on
the right. (The figure shows the
default values.)
5
Select User settings for Port 2:
Port settings from the pull-down
list of Set Value.
6
Set the following parameters in
the same way as step 5.
Serial communications mode:
Protocol macro
Data length: 8 bits
Stop bits: 1 bit
Parity: None
Baud rate: 38400bps
Protocol macro Transmission
method: Full-duplex
*Use the default settings for
other parameters.
Click Transfer[PC to Unit].