EasyManua.ls Logo

Omron CK3W-AX1515N - Page 192

Omron CK3W-AX1515N
218 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Default
Register name Sys.Default
Description Initialized to the factory default setting.
Range 0 to 1
Details 0: No error
1: Cases below
In the factory default state, or initialized to the factory default state by a re-initializa-
tion command ($$$***).
Configuration changed after save command was issued.
Detection timing When power is turned ON or reset
Recovery Cycle the power supply, reset command ($$$)
Effects Operation continues
Cause and cor-
rection
Cause (Assumed cause) Correction Prevention
Re-initialization command
($$$***) issued.
None None
HWChangeErr
or
ConfigLoadErr occurred.
Check the corrective action
for each error.
None
Precautions/
Remarks
None
FileConfigErr
Register name Sys.FileConfigErr
Description System file setting error
Range 0 to 1
Details 0: No error
1: System file setting error
Detection timing When power is turned ON or reset
Recovery Cycle the power supply, reset command ($$$)
Effects Operate at default settings.
Cause and cor-
rection
Cause (Assumed cause) Correction Prevention
System file settings are in-
correct.
If the re-initialization com-
mand ($$$***) is executed,
and the error no longer oc-
curs, review the user pro-
gram.
None
The CPU Unit or the CK3W
Unit has failed
If this error persists even
after you make the above
corrections, replace the
CPU Unit or the CK3W
Unit.
None
Precautions/
Remarks
None
6 Troubleshooting
6-14
CK3M-series Programmable Multi-Axis Controller User's Manual Hardware (O036)

Table of Contents

Related product manuals