7
Setting motor control
parameters
In the Solution Explorer, open
Project name PMAC Script
Language Global Includes
global definitions.pmh.
8
In the programming area of the
global definitions.pmh tab page,
write the set values to be set
automatically upon power-on.
Example settings are shown on
the right.
Motor[1].FatalFeLimit=0;
Motor[1].AbortTa= -0.1;
Motor[1].AbortTs= 0;
Motor[1].MaxSpeed= 5000;
Motor[1].JogTa= -0.1;
Motor[1].JogTs= -1;
Motor[1].JogSpeed= 1000;
Motor[1].HomeVel= 1000;
Coord[1].Tm=100;
Coord[1].FeedTime=60000;
Coord[1].MaxFeedRate=5000;