D4N
Contact Form
Note: Terminals are numbered according to EN50013 and the contact forms are according to IEC947-5-1.
* MBB (Make Before Break) contacts have an overlapping structure, so that before the normally closed contact (NC) opens, the normally open
contact (NO) closes.
Model Contact Contact form Operating pattern Remarks
D4N-@1@
1NC/1NO
(Snap-action)
D4N-@2@ 2NC (Snap-action)
D4N-@A@
1NC/1NO
(Slow-action)
D4N-@B@ 2NC (Slow-action)
D4N-@C@
2NC/1NO
(Slow-action)
D4N-@D@ 3NC (Slow-action)
D4N-@E@
1NC/1NO MBB *
(Slow-action)
D4N-@F@
2NC/1NO MBB *
(Slow-action)
14
32
13
31
Zb
ON
Stroke
13-14
31-32
Only NC contacts 31-32 have a
certified direct opening
mechanism.
The terminals 13-14 and 31-32
can be used as unlike poles.
11
31
12
32
Zb
ON
Stroke
11-12
31-32
Only NC contacts 11-12 and
31-32 have a certified direct
opening mechanism.
The terminals 11-12 and 31-32
can be used as unlike poles.
11
33
12
34
Zb
ON
Stroke
11-12
33-34
Only NC contacts 11-12 have a
certified direct opening
mechanism.
The terminals 11-12 and 33-34
can be used as unlike poles.
11
31
12
32
Zb
ON
Stroke
11-12
31-32
Only NC contacts 11-12 and
31-32 have a certified direct
opening mechanism.
The terminals 11-12 and 31-32
can be used as unlike poles.
33 34
11
21
12
22
Zb
ON
Stroke
21-22
33-34
11-12
Only NC contacts 11-12 and
21-22 have a certified direct
opening mechanism.
The terminals 11-12, 21-22, and
33-34 can be used as unlike
poles.
11
21
12
22
31 32
Zb
ON
Stroke
11-12
21-22
31-32
Only NC contacts 11-12, 21-22,
and 31-32 have a certified direct
opening mechanism.
The terminals 11-12, 21-22, and
31-32 can be used as unlike
poles.
11
33
12
34
Zb
ON
Stroke
11-12
33-34
Only NC contacts 11-12 have a
certified direct opening
mechanism.
The terminals 11-12 and 33-34
can be used as unlike poles.
33 34
11
21
12
22
Zb
ON
Stroke
11-12
21-22
33-34
Only NC contacts 11-12 and
21-22 have a certified direct
opening mechanism.
The terminals 11-12, 21-22 and
33-34 can be used as unlike poles.
http://www.ia.omron.com/
8
(c)Copyright OMRON Corporation 2007 All Rights Reserved.

Other manuals for Omron D4N Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron D4N Series and is the answer not in the manual?

Omron D4N Series Specifications

General IconGeneral
Voltage Rating250 VAC, 30 VDC
Ingress ProtectionIP67
Actuator TypePlunger
Current Rating10 A
Housing MaterialPlastic
CategorySwitch
Connection MethodScrew terminals
Operating Speed0.05 mm/s to 0.5 m/s
StandardsUL 508
Mechanical Life15, 000, 000 operations minimum
Electrical Life500, 000 operations
Contact Configuration1NC/1NO, 2NC