EasyManua.ls Logo

Omron E3ZM-V81 - Operating Procedures; Two-point Teaching Using Teaching Button

Omron E3ZM-V81
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E3ZM-V
11
Operating Procedure
Two-point Teaching Using Teaching Button
1. Place the point for which you want the output to go ON in the beam spot position.
Then, press and hold the teaching button for at least 2 seconds.
The teaching indicator (red) will begin flashing quickly. (This indicates that the output ON teaching
operation should begin.)
Perform the following operation within 7 seconds of when you start pushing the button. (After 7 seconds,
the Unit will return to its initial condition.)
2. Press the teaching button for approximately 0.5 second.
The teaching indicator (red) will light for approximately 0.5 second to show that the output ON
teaching is completed.
The teaching indicator (red) will then begin flashing quickly again to show that the output OFF teaching
operation should begin.
3. Place the point where you want the output to go OFF in the beam spot position.
4. Press the teaching button for approximately 0.5 second.
The teaching indicator (red) will light for approximately 0.5 second to show that the output OFF
teaching is completed.
When Teaching Is Successful When Teaching Is Not Successful
The stability indicator (green) shows that detection is stable.
The teaching indicator (red) flashes
slowly.
(Flashes in cycles of approx.
6 seconds.)
1.Lights
This indicates stable detection,
even if there is some fluttering
in the sensing object.
2.Flashes
This indicates the possibility of
unstable detection, due to
fluttering in the sensing object.
3.Remains OFF
This indicates unstable
detection.
Repeat the operation starting with step 1.
The Sensor enters normal operating condition.
Sensor
Background
Mar
k
Flashes quickly
Lit for approximately
0.5 second
Flashes quickly
Sensor
Background
Mark
Lit for approximately
0.5 second
Flashes slowly
Flashes
Off
Lit
Stable detection Unstable detection
ON point
OFF point
Lit Lit
Off Lit
Lit Off
Off Off

Related product manuals