Specifications
Time Ranges
Time unit 0.05 s 0.1 s 0.25 s 0.5 s
Setting 5 0.5to5s
10 1to10s
50 5to50s
100 10 to 100 s
Ratings
Rated supply voltage 100/110/120 or 200/220/240 VAC (50/60 Hz)
Operating voltage range 85% to 110% of rated supply voltage
Power consumption AC: approx. 10 VA/2 W
Control outputs 5 A at 250 VAC, resistive load (cos
%
=1)
Minimum permissible load (ref. value): 100 mA at 5 VDC
Characteristics
Accuracy of operating time
!
0.3%
Setting error
!
5%
Star-delta transfer time
!
25% + 5 ms
Reset time 0.5 s max.
Influence of voltage
!
0.5%
Influence of temperature
!
2% max.
Insulation resistance 100 M
$
min. (at 500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts and
between contact and control circuit)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm double amplitude
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude
Shock resistance Destruction: 1,000 m/s
2
(approx. 100G)
Malfunction: 300 m/s
2
(approx. 30G)
Ambient temperature Operating: --10
"
Cto55
"
C
Ambient humidity Operating: 35% to 85%
Life expectancy Mechanical: 20,000,000 operations min. (under no load at 1,800 operations/h)
Electrical: See
“Engineering Data.”
Approved standards UL (File No. E41515), CSA (File No. LR22310)
Weight H3BG-8, H3BG-8H: approx. 100 g; H3BG-F, H3BG-FH: approx. 170 g
Engineering Data
Switching operations (x 10 )
3
Load current (A)