EasyManuals Logo

Omron H3CR-A User Manual

Omron H3CR-A
326 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #315 background imageLoading...
Page #315 background image
Y92A-
jj
N
Y92A-
jj
N
315
Precautions
It is possible toopenorclosethefront cover by untightening or tight-
ening the knurled screw.
Be sure totake thespace requiredfortheopening and closing of the
front cover into consideration when installing the Watertight Cover.
The front cover is made of polycarbonbate, which can be cleaned
using water, methanol, or ethanol.
Regularly check the packing, the quality of which will deteriorate
over the process of time.
The front cover can be mounted in any direction.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. Q88-E1-1

Other manuals for Omron H3CR-A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron H3CR-A and is the answer not in the manual?

Omron H3CR-A Specifications

General IconGeneral
Time Range0.05 seconds to 300 hours
Output TypeRelay
Mounting TypeDIN Rail
Operating Temperature-10°C to 55°C
Contact FormSPDT
Number of Pins8
Contact Rating5A at 250VAC
Storage Temperature-25°C to 65°C
TypeSolid State Timer
Dimensions48 mm x 48 mm
Operating ModeON-delay, OFF-delay, Interval, One-shot
Operating Voltage24V DC, 100-240V AC