B-60 Solid-state Multi-functional Timer H3DE-M/-S
.
Note: The start input of the H3DE-M1 or H3DE-M2 model is activated by applying a voltage to B1 and A2 terminals.
The voltage can be applied by turning on the contact between B1 and A1 (Refer to Terminal Arrangement).
Operating
mode
Timing chart
D:
Signal OFF-
delay
E: Interval
G:
Signal ON/
OFF-
delay
J:
One-shot out-
put
(ON delay)
t
*
tt
tatata
Power (A1 and A2)
Power indicator
Basic operation
Power
Start
Output
Start (B
1 and A2)
(see note)
Output relay: NC 15
and 16 (25 and 26)
Output relay: NO
(output indicator)
15 and 18 (25 and 28)
* Start input is valid and re-triggerable while the
Timer is in operation.
Instantaneous contacts:
NC 25 and 26
Instantaneous contacts:
NO 25 and 28
t
**
tt
tata
t
Power
Output
Basic operation
Power (A1 and A2)
Power indicator
Start (B
1 and A2)
(see note)
Output relay: NC 15
and 16 (25 and 26)
Output relay: NO
(output indicator)
15 and 18 (25 and 28)
*
Start
* For power-on operation, impose voltage to the
Start input. The Timer starts operating at the
moment the power is turned on.
** Start input is valid and re-triggerable while the
Timer is in operation.
Instantaneous contacts:
NC 25 and 26
Instantaneous contacts:
NO 25 and 28
t t t t
*
tttt
tata
Power (A1 and A2)
Power indicator
Power
Start
Output
Basic operation
Start (B1 and A2)
(see note)
Output relay: NC 15
and 16 (25 and 26)
Output relay: NO
(output indicator)
15 and 18 (25 and 28)
* Start input is valid and re-triggerable while the
Timer is in operation.
Instantaneous contacts:
NC 25 and 26
Instantaneous contacts:
NO 25 and 28
t
**
tt
tata
t
Power (A1 and A2)
Power indicator
Power
Output
Basic operation
Start (B1 and A2)
(see note)
Output relay: NC 15
and 16 (25 and 26)
Output relay: NO
(output indicator)
15 and 18 (25 and 28)
Approx.
1+0.6 s
(fixed)
Approx.
1+0.6 s
(fixed)
Approx.
1+0.6 s
(fixed)
*
Start
Approx. 1+0.6 s
(fixed)
* For power-on operation, impose voltage to the
Start input. The Timer starts operating at the
moment the power is turned on.
** Start input is valid and re-triggerable while the
Timer is in operation.
Instantaneous contacts:
NC 25 and 26
Instantaneous contacts:
NO 25 and 28