B-24 Solid-state Twin Timer H3DS-F
Specifications
General
Note: Can be mounted to 35-mm DIN Track with a plate thickness of 1 to 2.5 mm.
Time Ranges
Note: When the time setting dial is set to “0” for any time scale, the output will operate instantaneously.
Ratings
Note: DC ripple rate: 20% max.
Item H3DS-F
Operating mode Flicker-OFF/Flicker-ON start
Output type Relay: SPDT
External connections Screw terminal, Screw-Less Clamp
Terminal block
Screw terminal type: Clamps two 2.5-mm
2
max. bar terminals without sleeves.
Screw-Less Clamp type: Clamps two 1.5-mm
2
max. bar terminals without sleeves.
Terminal screw tightening torque 0.98 N·m max.
Mounting method DIN track mounting (see note)
Attachment Nameplate label
Approved standards UL508, CSA C22.2 No.14
Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P 100
Output category according to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 1 A/DC-13; 30 V 0.1 A)
Time scale display Time range
0.1 s 0.1 to 1.2 s
1 s 1 to 12 s
0.1 m 0.1 to 1.2 min
1 m 1 to 12 min
0.1 h 0.1 to 1.2 h
1 h 1 to 12 h
Rated supply voltage (See note.) 24 to 230 VAC (50/60 Hz)/24 to 48 VDC
Operating voltage range 85% to 110% of rated supply voltage
Power reset Minimum power-off time: 0.1 s
Reset voltage 2.4 VAC/DC max.
Power consumption AC: 33 VA max./2.2 W max. (typical: 31 VA/2.0 W) at 230 VAC
11 VA max./1.9 W max. (typical: 9.7 VA/1.7 W) at 100 to 120 VAC
DC: 0.7 W max. (typical: 0.6 W) at 24 VDC
1.4 W max. (typical: 1.2 W) at 48 VDC
Voltage input Max. permissible capacitance between inputs lines (terminals B1 and A2): 2,000 pF
Load connectable in parallel with inputs (terminals B1 and A1).
H-level: 20.4 to 253 VAC/20.4 to 52.8 VDC
L-level: 0 to 2.4 VAC/DC
Control output Contact output: 5 A at 250 VAC with resistive load (cosφ = 1)
5 A at 30 VDC with resistive load (cosφ = 1)
Ambient temperature Operating: –10°C to 55°C (with no icing)
Storage: –25°C to 65°C (with no icing)
Ambient humidity Operating: 35% to 85%