H7CX-A@-N
21
Counter
Input Modes and Present Value (See note 1.)
I/O Functions for Counter Operation
UP (Increment) Mode DOWN (Decrement) Mode
CP1: Count input; CP2: Prohibit (gate) input
must be greater than the minimum signal width. (See note 2.)
CP1: Count input; CP2: Prohibit (gate) input
must be greater than the minimum signal width. (See note 2.)
CP1: Prohibit (gate) input; CP2: Count input
must be greater than the minimum signal width. (See note 2.)
CP1: Prohibit (gate) input; CP2: Count input
must be greater than the minimum signal width. (See note 2.)
* Counting starts when the CP1 is turned ON after turning ON the power.
UP/DOWN A Command Input Mode UP/DOWN B Individual Input Mode
must be greater than the minimum signal width. (See note 2.)
UP/DOWN C Quadrature Input Mode
Note: 1. If the configuration selection is set to dual counter, CP1 and
CP2 input will operate in the same way as the count input
(CP1) of UP (increment) mode.
2. must be greater than the minimum signal width and
must be at least 1/2 the minimum signal width.
If they are less, a count error of ±1 may occur.
Minimum signal width: 16.7 ms (when maximum counting speed = 30 Hz)
100 µs (when maximum counting speed = 5 kHz)
3. The meaning of the H and L symbols in the tables is explained
below.
must be at least 1/2 the minimum signal width. (See note 2.)
0
CP1
H
L
CP2
Present value
H
L
0
1
2
4
3
5
Prohibit
A A
A
n
CP1
H
L
CP2
Present value
H
L
0
n1
n2
n4
n3
n5
A A
Prohibit
A
0
*CP1
H
L
CP2
Present value
H
L
0
1
2
4
3
5
A A
Prohibit
A
n
*CP1
H
L
CP2
Present value
H
L
0
n1
n2
n4
n3
n5
A A
Prohibit
A
0
CP1
H
L
CP2
Present value
H
L
0
1
2
2
2
1
3
3
A A
A
0
CP1
H
L
CP2
Present value
H
L
0
1
2
2
2
11
3
3
A
B
Symbol
Input method
No-voltage input
(NPN input)
Voltage input (PNP
input)
H Short-circuit 4.5 to 30 VDC
L Open 0 to 2 VDC
0
CP1
H
L
CP2
Present value
H
L
0
1
2
2
2
1
3
3
B B B B
B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron H7CX- -N Series and is the answer not in the manual?

Omron H7CX- -N Series Specifications

General IconGeneral
Input TypeContact input
Output TypeRelay
Counting ModeCount up/down
Reset MethodManual or external signal
Operating Temperature-10 to 55°C (with no icing or condensation)
Storage Temperature-25 to 65°C (with no icing or condensation)
MountingPanel mount
Supply Voltage100-240V AC