EasyManua.ls Logo

Omron H7CX- -N Series User Manual

Omron H7CX- -N Series
57 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
New Product
Multifunction Counter/Tachometer
H7CX-@-N
Ultra-compact Counter Provides More
Complete Functionality.
Basic Features
Short body with depth of only 59 mm (for 12 to 24-VDC Models with Screw Terminals).
*1
Better readability with character height of 12 mm on 4-digit models and 10 mm
on 6-digit models.
The present value display characters can be switched between red, green, and orange.
*2
Safety and Reliability
New set value limit and counter functions have been added.
Other Features
Front Panel can be changed to white or light gray.
*3
New models with two tachometer inputs and two tachometer outputs have
been added to the series.
*4
*1.For 100 to 240-VAC Models with Screw Terminals: 78 mm, Models with Sockets: 63.7 mm
(case dimension).
*2.The H7CX-A11 and H7CX-R11 have only red characters.
*3.
The Front Panel can be replaced with an optional Front Panel (except for Tachometer-only Models).
*4.Only one prescale value provided.
Features
Basic Features
Ultra Short Body
The body depth has been greatly reduced. Helps in making thinner control panels.
Easier to Read
For better readability, the character height for the present value
display is 12 mm on models with 4 digits, the largest class in the
industry. The wide viewing angle and brightness provide excellent
visibility. The number of display segments has also been increased to
make settings easier to understand, and the present value display
can be switched between red, green, and orange so that output status
can be seen from a distance.
Note: The display color can be switched on all models except for the
H7CX-A11 and H7CX-R11.
The Easiest Operation
Operation is simplified by the
Up/Down Key for each digit
on 4-digit models and Up
Key for each digit on 6-digit
models.
Safety and Reliability
Isolated Power Supply and Input Circuits
Power supply circuit and input circuits are isolated inside the Counter/
Tachometer. Previous non-isolated counters had wiring restrictions
and could be damaged if wired incorrectly. The H7CX removes these
worries.
Note: Except 12 to 24-VDC models.
Set Value Limit
You can set an upper limit for the set value to prevent unexpected
operation of output devices caused by setting mistakes.
Output Counter
The output counter counts the number of times the output turns ON
(alarms can be displayed and the count can be monitored in
increments of 1,000 operations). This counter is useful in managing
the service life of the Counter/Tachometer or the load.
Refer to Safety Precautions on page 52.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
12 to 24-VDC Models with Screw Terminals: 59 mm
100 to 240-VAC Models with Screw Terminals: 78 mm*
Models with Sockets: 63.7 mm (case dimension)
* Power supply circuit and input circuits are isolated for safety and reliability.
New models
Previous
models
12 mm
(actual size)
Model with 4 Digits Model with 6 Digits
10 mm
(actual size)
(Display example)
New
models
Previous
models
Easy to read from the top, bottom,
and sides!
Model with 4 Digits Model with 6 Digits
For 1,000 pieces
No overflow
Setting the upper limit of the set
value enables worry-free operation.
Question and Answer IconNeed help?

Do you have a question about the Omron H7CX- -N Series and is the answer not in the manual?

Omron H7CX- -N Series Specifications

General IconGeneral
Input TypeContact input
Output TypeRelay
Counting ModeCount up/down
Reset MethodManual or external signal
Operating Temperature-10 to 55°C (with no icing or condensation)
Storage Temperature-25 to 65°C (with no icing or condensation)
MountingPanel mount
Supply Voltage100-240V AC

Summary

Multifunction Counter/Tachometer H7CX--N

Ultra-compact Counter Provides More Complete Functionality

Highlights the product's compact size and enhanced functionality.

Basic Features

Details fundamental characteristics like short body and readability.

Safety and Reliability

Covers safety aspects and added reliability features.

Other Features

Lists additional features like changeable front panels and tachometer inputs.

Ultra Short Body

Focuses on the reduced body depth for panel design.

Easier to Read

Emphasizes display readability, viewing angle, and brightness.

The Easiest Operation

Describes simplified operation with digit keys.

H7CX--N Other Features and Model Structure

Key Protection

Explains selectable protection patterns for preventing unauthorized operation.

New Tachometer Functions

Details advanced tachometer capabilities like dual inputs and output hysteresis.

Model Number Structure

Provides a guide to understanding the model numbering system.

Model Configuration

Shows the various H7CX series models and their classifications.

Model Number Legend and Ordering Information

Model Number Legend

Explains the components and meaning of the model number.

Ordering Information

Lists available models with their configurations, connections, and specifications.

Accessories for H7CX Series

Front Panels (Replacement Part)

Details replacement front panels for changing the unit's color.

Flush Mounting Adapter

Explains the adapter for flush mounting and its use.

Waterproof Packing

Details the waterproof packing for IP66 protection.

Connection Sockets

Lists connection sockets for mounting the unit.

H7CX-A-N Multifunction Preset Counter Specifications

Specifications

Comprehensive technical specifications of the H7CX-A-N models.

H7CX-A-N Tachometer Function Ratings and Characteristics

Tachometer Function Ratings

Detailed technical ratings specific to the tachometer function.

Characteristics

Physical and electrical characteristics, including insulation and vibration resistance.

Applicable Standards

Lists safety and EMC standards the product complies with.

H7CX-A-N Counter I/O Functions and Operation

I/O Functions for Counter Operation

Explains how inputs and outputs function when used as a counter.

Operating Procedures (Tachometer Function)

Outlines operating procedures specifically for the tachometer function.

H7CX-A-N Connections and Input Circuits

Connections

Illustrates terminal arrangements for various H7CX-A-N models.

Terminal Arrangement

Shows the physical layout of terminals for different configurations.

Transistor Output

Explains the functionality of transistor outputs and their isolation.

H7CX-A-N Input Circuits and Signal Levels

Block Diagram

Provides a high-level overview of the unit's internal structure.

Input Connections

Shows how to connect various input devices like sensors and PLCs.

No-voltage Inputs (NPN Inputs)

Explains connection and signal levels for NPN inputs.

Voltage Inputs (PNP Inputs)

Explains connection and signal levels for PNP inputs.

H7CX-A-N Nomenclature and Dimensions

Nomenclature

Identifies and explains the components of the unit's front panel.

Display Section

Details the various indicators and displays on the front panel.

Operation Keys

Describes the function of each key on the front panel.

Switches

Explains the key-protect and DIP switches.

Dimensions

Provides the physical dimensions of the counter units.

H7CX-A-N Flush Mounting Dimensions and Cutouts

Flush Mounting Dimensions

Shows dimensions for flush mounting models.

Dimensions with Flush Mounting Adapter

Shows dimensions when using flush mounting adapters.

Panel Cutouts

Specifies the required panel cutout dimensions for flush mounting.

H7CX-A-N Accessories

Front Panel (Replacement Part)

Details replacement front panels for changing the unit's color.

Protecting the Counter/Tachometer in Environments Subject to Oil

Advises on using soft covers for oil protection.

Flush Mounting Adapter

Explains the adapter for flush mounting and its use.

Waterproof Packing

Details the waterproof packing for IP66 protection.

Connection Sockets for H7CX Series

Front Connecting Socket

Specifications for front connecting sockets.

Back-connecting Sockets

Specifications for back-connecting sockets.

Optional Products for Track Mounting

Mounting Track

Specifications for mounting tracks.

End Plate

Specifications for end plates used with mounting tracks.

Spacer

Specifications for spacers used with mounting tracks.

Operating Procedures and I/O Functions for Counter

Setting Procedure Guide

Step-by-step instructions for setting up the counter.

I/O Functions for Counter Operation

Explains how inputs and outputs function for counter operations.

H7CX-A-N Counter Function Setting Mode

Function Setting Mode

Details how to set parameters using front panel keys.

H7CX-A-N Counter Function Setting Mode Details

Absolute value value setting

Setting for absolute value and forecast value.

Set value upper limit

Setting the upper limit for the set value.

Forecast setting upper limit

Setting the upper limit for the forecast set value.

Batch count upper limit

Setting the upper limit for the batch count value.

H7CX-A-N Counter Explanation of Functions

Explanation of Functions

Detailed explanation of various counter functions and settings.

Input Mode (nm)

Explanation of input modes like UP, DOWN, and quadrature.

Prescale Value (PSCL)

How to set prescale values for unit conversion.

NPN/PNP Input Mode (mad)

Setting the input format for sensors.

H7CX-A-N Counter Function Details

Absolute Value Setting/Forecast Value Setting (5)

Details on setting absolute and forecast values for 2-output modes.

Set Value Upper Limit (SL-H)

Setting the upper limit for the set value.

Forecast Set Upper Limit (PL-H)

Setting the upper limit for the forecast set value.

Key Protect Level (KYPE)

Setting the key protect level to restrict operation.

H7CX-A-N Counter Operation in Run Mode

Operation in Run Mode

Explains how the counter operates in run mode for various configurations.

I/O Functions for Counter Operation

Details I/O functions in run mode for different counter types.

H7CX-A-N Counter Input Modes and I/O Functions

Input Modes and Present Value (See note 1.)

Illustrates input modes and corresponding present value changes.

I/O Functions for Counter Operation

Explains I/O functions for counter operations.

H7CX-A-N Counter Input/Output Mode Settings

Input/Output Mode Settings

Details output mode settings and their operation with different input modes.

I/O Functions for Counter Operation

Explains I/O functions for counter operations.

H7CX-A-N Counter Input/Output Mode Settings Continued

Input/Output Mode Settings

Continues detailing output mode settings and their operation.

H7CX-A-N Counter Input/Output Mode Settings for UP/DOWN

Input/Output Mode Settings

Details output mode settings and their operation for UP/DOWN A, B, C input modes.

H7CX-A-N Counter Operation Modes

Total and Preset Counter Operation

Explains the operation of total and preset counters.

Batch Counter Operation

Explains the operation of batch counters.

Dual Counter Operation

Explains the operation of dual counters, including ADD/SUB modes.

H7CX-A-N Counter Twin Counter and Reset Functions

Twin Counter Operation

Details the operation of twin counters.

Reset Function List

Lists reset functions for various counter types.

I/O Functions for Counter Operation

Explains I/O functions for counter operations.

H7CX-A-N Tachometer Setting Procedures

Setting Procedure Guide

Step-by-step guide for setting up tachometer operation.

Tachometer Operation

Guides on entering configuration and setting tachometer mode.

Set the basic parameters.

Setting basic parameters using DIP switches and front panel keys.

H7CX-A-N Tachometer Function Setting Mode

Function Setting Mode

Details parameter settings using front panel keys for tachometers.

H7CX-A-N Tachometer Function Setting Mode Details

NPN/PNP Input Mode (d)

Setting the input format for sensors.

Display Color (LOL)

Setting the display color for measurement values.

Output Hysteresis (495)

Setting hysteresis to prevent output chattering.

Set Value Upper Limit (PL-H)

Setting the upper limit for the set value.

H7CX-A-N Tachometer Function Explanation

Explanation of Functions

Detailed explanation of tachometer functions and settings.

Tachometer Input Mode (円)

Explains input modes for tachometer operation.

Prescale Value (PSC1)

How to set prescale values for unit conversion.

Auto-zero Time (AutoD)

Setting auto-zero time to reset the display to zero.

H7CX-A-N Tachometer Function Settings

NPN/PNP Input Mode (d)

Setting the input format for sensors.

Display Color (LOL)

Setting the display color for measurement values.

Output Hysteresis (495)

Setting hysteresis to prevent output chattering.

Set Value Upper Limit (PL-H)

Setting the upper limit for the set value.

H7CX-A-N Tachometer Alarm and Monitor Values

H7CX-A-N Tachometer Operation in Run Mode

Operation in Run Mode

Explains tachometer operation in run mode.

Peak/bottom hold value

Details how peak and bottom hold values are displayed.

H7CX-RO-N Tachometer Output Mode Settings

Models Other Than H7CX-R11W in Tachometer Mode

Operation details for various output modes in tachometer mode.

Models Other Than H7CX-R11W in AMD-compatible Mode

Operation details for various output modes in AMD-compatible mode.

H7CX-A-N Mode Switching and Hold Function

Hold Function

Explains the hold function for measurement values and outputs.

H7CX-A-N Key Protect Level and Self-diagnostic Function

Key Protect Level

Details the key protect levels and their effects on operation.

Self-diagnostic Function

Describes error displays and their correction methods.

H7CX-R-N Tachometer Specifications

Specifications

Comprehensive technical specifications for H7CX-R-N tachometers.

H7CX-RO-N Characteristics and I/O Functions

Characteristics

Physical and electrical characteristics, including insulation and vibration resistance.

Applicable Standards

Lists safety and EMC standards the product complies with.

I/O Functions

Explains I/O functions for tachometers.

H7CX-RO-N Connections and Input Circuits

Connections

Shows terminal arrangements and block diagrams for H7CX-R models.

Terminal Arrangement

Illustrates terminal layouts for different H7CX-R models.

Input Circuits

Details the internal circuits for count and hold inputs.

H7CX-RO-N Input Connections

Input Connections

Explains input connections for various sensor types.

No-voltage Inputs (NPN Inputs)

Details NPN input connections and signal levels.

Voltage Inputs (PNP Inputs)

Details PNP input connections and signal levels.

H7CX-R-N Nomenclature and Dimensions

Nomenclature

Identifies and explains the components of the unit's front panel.

Dimensions

Provides physical dimensions for tachometers.

Panel Cutouts

Specifies panel cutout dimensions for flush mounting.

H7CX-RO-N Accessories

Accessories (Order Separately)

Lists optional accessories for tachometers.

Flush Mounting Adapter

Explains the adapter for flush mounting and its use.

Waterproof Packing

Details the waterproof packing for IP66 protection.

H7CX-RO-N Operating Procedures

Operating Procedures

Guides on setting basic parameters using DIP switches for tachometers.

Step1 Set the basic parameters.

Step-by-step instructions for setting basic tachometer parameters.

H7CX-RO-N Tachometer Function Setting Mode

Function Setting Mode

Details parameter settings using front panel keys for tachometers.

H7CX-R-N Tachometer Function Explanation

Explanation of Functions

Detailed explanation of tachometer functions and settings.

Decimal Point Position (DP)

How to set the decimal point position for measurement values.

Prescale Value (PSC1)

How to set prescale values for unit conversion.

Auto-zero Time (AutoD)

Setting auto-zero time to reset the display to zero.

H7CX-RO-N Tachometer Settings and Protect Level

Startup Time (5m)

Setting a delay to prevent undesired output on startup.

Key Protect Level (YPE)

Setting the key protect level to restrict operation.

Output ON Count Alarm Set Value (n-A)

Setting alarm values for output ON counts.

H7CX-RO-N Tachometer Operation in Run Mode

Operation in Run Mode

Explains tachometer operation in run mode for different output modes.

H7CX-RO-N Key Protect Level and Self-diagnostic Function

Key Protect Level

Details the key protect levels and their effects on operation.

Self-diagnostic Function

Describes error displays and their correction methods.

H7CX-RO-N Tachometer Output Mode Settings

Output Mode Settings

Explains output mode settings and their operations for tachometers.

H7CX-RO-N Precautions and DIP Switch Monitor

Precautions for the H7CX-R

Important precautions for using the H7CX-R series.

Hold Function

Explains the hold function for measurement values and outputs.

Operation in DIP Switch Monitor Mode

How to use the DIP switch monitor mode to check settings.

H7CX-RO-N Precautions on AMD-S Replacement

Precautions on Replacing the AMD-S

Precautions for replacing the AMD-S with the H7CX-R11-N.

Terminal Arrangement and Wiring Connections

Shows wiring connections and terminal arrangements for AMD-S replacement.

Setting Procedure

Steps for setting functions to match AMD-S.

DIP Switch Settings

Details DIP switch settings for AMD-S replacement.

Safety Precautions for All H7CX Series

Safety Precautions for All H7CX Series (Common)

General safety precautions applicable to all H7CX series models.

Precautions for Safe Use

Guidelines for safe usage, including environmental considerations and installation.

H7CX--N Precautions for Correct Use and Standards

Precautions for Correct Use

Specific precautions for correct usage, including power supply and environmental factors.

Conformance to EN/IEC Standards

Information regarding compliance with EN/IEC standards and EMC.

Warranty and Application Considerations

Warranty and Limitations of Liability

OMRON's warranty terms and liability limitations.

Application Considerations

Guidelines for product suitability and safe application.

Related product manuals