Cam Positioner
H8PS
C-159
Counters
Connections
Terminal Arrangement
Note:
Internal circuit damage can result from a short circuit in the load.
Item H8PS-8B/-8BF H8PS-8BP/-8BFP
RUN OUT Output 1 to 8 TACHOMETER RUN OUT Output 1 to 8 TACHOMETER
Output method
NPN open collector PNP open collector
Dielectric strength
30 V 30 V
Rated current
100 mA 30 mA 100 mA 30 mA
Residual voltage
2 V max. 0.5 V max 2 V max.
Leak current
100
µ
A max. 5
µ
A max. 100
µ
A max.
H8PS-8B H8PS-8BF
H8PS-8BP H8PS-8BFP
Output Circuit
Output Circuit
(Rated voltage: 24 VDC)
*When using an inductive load, connect a
reverse surge-absorbing diode.