9-13
9-4 Setting the Mode
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
9
Operation
Alarm Codes and Meanings
Note. The following alarms are not recorded in the history.
11: Control power supply undervoltage
13: Main power supply undervoltage
36: Parameter error
37: Parameters destruction
38: Drive prohibition input error
95: Motor non-conformity
Alarm
codes
Contents
Alarm
codes
Contents
11 Control power supply undervoltage 36 Parameter error
12 Overvoltage 37 Parameters destruction
13 Main power supply undervoltage 38 Drive prohibition input error
14 Overcurrent 39 Excessive analog input
15
Servo Drive overheat
40
Absolute encoder system down
error
16
Overload
41
Absolute encoder counter overflow
error
18
Regeneration overload
42
Absolute encoder overspeed error
21
Encoder communications error
44
Absolute encoder 1-rotation counter
error
23
Encoder communications data error
45
Absolute encoder multi-rotation counter
error
24 Error counter overflow 46 Encoder error 1
26
Overspeed
47
Absolute encoder status error
27 Electronic gear setting error 48 Encoder phase-Z error
34 Overrun limit error 49 Encoder CS signal error
ABS
ABS
ABS
ABS
ABS
ABS