9-12
9-4 Setting the Mode
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
9
Operation
Analog Input Value
Alarm Factor, History
Up to the most recent 14 alarms, including the current one, can be viewed in the reason of error.
The display area will flash when an alarm occurs.
If an alarm that is recorded in the history occurs, the alarm code for the current alarm and for
history 0 will be the same.
"st" will flash on the display if a safety input error (alarm 30.0) occurs.
Analog input value 1 (V)
The value after offset compensation is displayed.
Analog input value 2 (V)
Analog input value 3 (V)
Input signal Input voltage (V)
Note. Voltages exceeding
+
/
10 V are not displayed accurately.
Press to select the signal you want to monitor.
...Present alarm
...History 0 (latest history)
...History 13 (oldest history)
Alarm code
( if no alarm is present)