27
V700-L21
User's Manual
Section 2
2.3 IDR/W head: Model V700-HMD13
Section 2
Unit Specifications
2.3.3 Dimensional drawing and mounting method
IDR/W head with mounting brackets installed
IDR/W head proper
Case sideplate Aluminum plate (A5052P) (Unit: mm)
Communication area on case Bakelite
Mounting bracket SUS 304 (t=1.0)
Cable PVC cable
(FOUP side)
8-core, standard length, 1 m
PVC-insulated round cable 6 (7/ 0.18)
Coil
4-M4
32
8.4
44
119.8
149.8
Mounting bracket
(material: SUS 304)
73
4- 4.5
44.8
17.0
(material: SUS 304)
Mounting bracket
45
57
22.4
36.4
4-M4
11.5 cable lead-in hole
Coil
17.0
44.8
119.8
44.8
57
22.4
36.4
8.4
4-M4
11.5 cable lead-in hole
119.8
73

Table of Contents