39
V700-L21
User's Manual
Section 3
3.2 System configuration example
Section 3
System Connections
3.2 System configuration example
A typical example of a CIDRW controller connected to a plurality of heads is given below.
Upstream controller
Head
"HeadID" "02"
Head
"HeadID" "03"
Head
"HeadID" "N"
Head
"HeadID" "01"
24V+
24V-
24 V
power
supply
54321
24V-
24V+
54321
24V-
24V+
54321
24V-
24V+
54321
24V-
24V+
24 V
power
supply
24 V
power
supply
24 V
power
supply
24 V
power
supply
Total cable length: max. 50 m
SW1-5: Node 1
SW10: Terminator /ON
SW1-5: Node 2
SW10: Terminator /OFF
SW1-5: Node 3
SW10: Terminator /OFF
SW1-5: Nth node
SW10: Terminator /ON

Table of Contents