EasyManua.ls Logo

Omron V700-HMD13 series - Acknowledge Message Received (Other than SSACK=NO)

Omron V700-HMD13 series
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
75
V700-L21
User's Manual
Section 7
7.2 Acknowledge message received (other than SSACK="NO")
Section 7
Troubleshooting
7.2 Acknowledge message received (other than
SSACK="NO")
Acknowledge Typical checkpoint
S×F0 • Status conditions at the time a message was issued.
Ex.: Write ID (S18F11) in Operating mode, or a message during initializing
S9F7 • Problematic message structure such as illegal attribute, excessive/insufficient items
SSACK="CE" • Wrong item contents in message
Ex.: Node No. as "Head ID" was assigned to a head that was not yet registered.
• Connection of RS-485 cable between link units (head not yet detected)
• Baud rate setting for link unit (head not yet detected)
• Node No. setting for link unit (particular node No. has been assigned to two or more link units, and correct
link unit cannot be detected)
• Routing of cable between upstream controller and CIDRW controller (adverse effect by external noise
interference)
• Noise environment around the power line of CIDRW controller
SSACK="EE" • Mounting distance and inclination between ID tag and IDRW head(s)
• Noise environment around IDRW head
• Spacing to IDRW head connected to another CIDRW system
SSACK="HE" • Connection of IDRW head, and wiring connections of extension cable
• Cable connection and wiring connections between CIDWR controller and link unit
• Power supply to link unit
• Setting of terminator on link unit
• Routing of various cables (adverse effect by external noise interference)
• Node No. setting for link unit (particular node No. has been assigned to two or more link units)
• Noise environment around power line
SSACK="TE" • Model and specifications of ID tag used
• Setting of ID tag used (write protect, etc.)
• Operating environment of tag (damaged ID tag by misoperation or misuse)
• Life of ID tag in terms of number of rewrite operations (100,000 cycles)

Table of Contents