EasyManua.ls Logo

Omron V700-HMD13 series - Page 48

Omron V700-HMD13 series
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
46
Section 4
4.3 Support attributes
V700-L21
User's Manual
Section 4
SECS Protocol Specifications
(2) Reader/Writer head attribute definitions
Attribute name Description Access Requested Form
Fundamental
Head Status Current state RO Y 20
"IDLE"
"BUSY"
"NOOP"
Head ID Head number 1-31 RO Y
(multi)
20
"01"-"31"
* "00" represents the CIDRW itself, and must
not be used.
Optional
Cycles Number of read and
write operations per-
formed
RO N 54 (4-byte unsigned integer)
* Not yet supported with this CIDRW system
Head Condition Current maintenance
status
RO N 20
NO: no alarms
NM: Needs maintenance.
RW: Read/write fault
RT: Read/write rate fault
* Not yet supported with this CIDRW system
NP: No power or connection error
(Head Date Installed) Date this head was
installed
RO N 20 "YYYYMMDD"
* Not yet supported with this CIDRW system
(Head Maintenance Data) Supplier dependent RO N 20
* Not yet supported with this CIDRW system

Table of Contents

Related product manuals