New Product Information Sheet
Specifications subject to change
© OMRON HEALTHCARE EUROPE B.V.
Model (code):
M3 Comfort (HEM-7155-E(C))
Versions
Remark
Date
1
Complete NPIS
17.11.2021
Question and Answer IconNeed help?

Do you have a question about the Omron X3 Comfort and is the answer not in the manual?

Summary

How to Use the Device

Main Steps

Provides a step-by-step guide for operating the blood pressure monitor.

Operation and Care

Cleaning of the Device

Instructions for cleaning the blood pressure monitor and its components.

Handling and Usage Cautions

AC Adapter Handling

Details on safe handling and usage of the AC adapter.

Battery Handling

Guidelines for safely handling and using the device batteries.

Operational Precautions

Measurement Preparation

Steps and recommendations before taking a blood pressure measurement.

Warranty and Servicing

Warranty and Lifetime

Details on the warranty period for the monitor, cuff, and AC adapter.

Summary

How to Use the Device

Main Steps

Provides a step-by-step guide for operating the blood pressure monitor.

Operation and Care

Cleaning of the Device

Instructions for cleaning the blood pressure monitor and its components.

Handling and Usage Cautions

AC Adapter Handling

Details on safe handling and usage of the AC adapter.

Battery Handling

Guidelines for safely handling and using the device batteries.

Operational Precautions

Measurement Preparation

Steps and recommendations before taking a blood pressure measurement.

Warranty and Servicing

Warranty and Lifetime

Details on the warranty period for the monitor, cuff, and AC adapter.

Overview

The OMRON M3 Comfort (HEM-7155-E(C)) is an automatic upper arm blood pressure monitor designed for general household use. It utilizes the oscillometric method of blood pressure measurement, detecting blood movement through the brachial artery and converting these movements into a digital reading. This device is clinically validated for use in general populations, as well as for pregnant individuals and those with diabetes.

Function Description:

The M3 Comfort measures blood pressure (SYS 60 to 260 mmHg, DIA: 40 to 215 mmHg) and pulse rate (40 to 180 beats/min) in adult patients. It features irregular heartbeat detection, alerting the user during a reading if an irregular heartbeat is detected. The device also includes a cuff wrap guide to ensure the cuff is wrapped correctly for accurate results. It stores up to 60 readings per user for two users, and also offers a guest mode. The monitor operates in continuous operation mode.

Important Technical Specifications:

  • Model Code: M3 Comfort (HEM-7155-E(C))
  • Measurement Method: Oscillometric method
  • Display: LCD digital display
  • Cuff Pressure Range: 0 to 299 mmHg
  • Blood Pressure Measurement Range: SYS 60 to 260 mmHg, DIA: 40 to 215 mmHg
  • Pulse Measurement Range: 40 to 180 beats/min
  • Accuracy: Pressure ± 3mmHg, Pulse ± 5% of display reading
  • Inflation: Automatic by electric pump
  • Deflation: Automatic pressure release valve
  • IP Classification: Monitor: IP 20; Optional AC adapter: IP21
  • Rating: DC6 V 4.0 W
  • Applied Part: Type BF (arm cuff)
  • Power Source: 4 "AA" batteries 1.5 V or optional AC adapter (input AC 100-240 V 50-60 Hz 0.12 -0.065 A)
  • Battery Life: Approximately 1000 measurements (using new alkaline batteries)
  • Durable Period (Service Life): Monitor: 5 years; Cuff: 5 years; Optional AC adapter: 5 years
  • Operating Conditions: +10 to +40 °C / 15 to 90% RH (non-condensing) / 800 to 1060 hPA
  • Storage / Transport Conditions: -20 to +60 °C / 10 to 90% RH (non-condensing)
  • Protection against electric shock: Internally powered ME equipment (when using only batteries) Class II ME equipment (optional AC adapter)
  • Dimensions (approximate value): Monitor: 105 mm (W) × 85 mm (H) × 152 mm (L); Arm cuff: 145 mm × 532 mm (air tube: 750 mm)
  • Weight (approximate value): Monitor: 340 g (not including batteries); Arm cuff: 163 g
  • Materials:
    • Main Unit Housing, Battery Cover, Front Panel, Button: ABS (acrylonitrile butadiene styrene)
    • Package: Coated board
    • Instruction Manual: Paper
    • Cuff (Cloth, fabric): Nylon, PVC (Polyvinyl Chloride)
    • Cuff (Air Tube): PVC (Polyvinyl Chloride)
    • Cuff (Air plug to device): ABS (acrylonitrile butadiene styrene)
    • Cuff (Air plug to cuff): PC (Polycarbonate)
    • AC Adapter (DC Cord): PVC (Polyvinyl Chloride)
    • AC Adapter (Print case): PPE (Polyphenylene Ether)

Usage Features:

The device comes with an Intelli Wrap Cuff (HEM-FL31) designed to provide accurate results in any position around the upper arm. It supports two users with 60 memories each, plus a guest mode. A cuff wrap guide helps ensure correct cuff application. The monitor is supplied with 4 "AA" batteries, a storage case, and two instruction manuals. Optional accessories include an AC adapter (HHP-CM01) and an AC Adapter UK version (HHP-BFH01).

To use the device:

  1. Prepare for measurement: Avoid alcohol, smoking, hot showers, hot beverages, eating, or exercising 30 minutes prior. Relax for 5 minutes before.
  2. Install batteries.
  3. Set the date and time.
  4. Apply the arm cuff on the left arm (or right arm, consulting IM1 Chapter 2.3).
  5. Sit correctly, place the arm at heart level, remain still, and avoid talking.
  6. Select user ID.
  7. Take the measurement by pressing the START/STOP button.
  8. Check readings, consulting IM2 Section 9 for symbol explanations.
  9. Utilize memory functions (stored readings, average of latest 2-3 readings, clear memory) after selecting a user ID.

Maintenance Features:

  • Cleaning: The device should be cleaned with a soft dry cloth or a soft cloth moistened with neutral soap. Abrasive or volatile cleaners, gasoline, thinners, or similar solvents should not be used. The monitor and arm cuff should not be washed or immersed in water.
  • Regular Maintenance: This device does not require any regular maintenance.
  • Storage: When not in use, store the monitor in its storage case. Remove the arm cuff from the monitor by pulling on the plastic air plug at the base of the tube. Gently fold the air tube into the arm cuff, avoiding excessive bending or creasing. Store the monitor and components in a clean, safe location, away from extreme temperatures, humidity, direct sunlight, dust, corrosive vapors, vibrations, shocks, or angled positions. Ensure the device is dry before storage.
  • Servicing: The accuracy of the blood pressure monitor is carefully tested. It is recommended to have the unit inspected every two years to ensure correct functioning and accuracy. Consult an authorized OMRON dealer or OMRON Customer Service for servicing.
  • Warranty: The monitor has a 3-year warranty, while the cuff and optional AC adapter have a 1-year warranty. The service life for the monitor, cuff, and AC adapter is 5 years. Warranty is granted only if the complete product is returned with the original invoice/cash ticket.
  • Disposal: Household users should contact their retailer or local government office for environmentally safe recycling instructions.

Omron X3 Comfort Specifications

General IconGeneral
ModelX3 Comfort
CategoryBlood Pressure Monitor
Cuff TypeComfort Cuff
Cuff Size22-42 cm
Measurement MethodOscillometric
DisplayLCD
Device TypeUpper Arm Blood Pressure Monitor
Irregular Heartbeat DetectionYes
Clinically ValidatedYes
MemoryYes
Average Reading FunctionYes
Cuff Wrapping GuideYes
Movement DetectionYes
Measurement Range (Pressure)0-299 mmHg
Power Source4 x AA batteries
Measurement Range (Pulse)40-180 beats/min
Weight340 g (excluding batteries)
Memory Capacity60 readings