F-164 General-purpose Basic Switch Z
Z-01H
Z-10F
Note: 1. The above current ratings are the values of the steady-state current.
2. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
5. The normally closed and normally open ratings of reverse hinge lever models are opposite to each other.
6. The AC ratings of molded terminals are 125 and 250 V only.
7. The ratings values apply under the following test conditions:
Ambient temperature: 20±2°C
Ambient humidity: 65±5%
Operating frequency: 20 operations/min
Rated voltage Resistive load
NC NO
125 VAC 0.1 A
8 VDC
14 VDC
30 VDC
0.1 A
0.1 A
0.1 A
Model Rated voltage Non-inductive load Inductive load
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
Series
connection
125 VAC
250 VAC
10 A
10 A
4 A
2.5 A
2 A
1.5 A
6 A 5 A
3 A
2.5 A
1.5 A
30 VDC
125 VDC
250 VDC
10 A
1 A
0.6 A
4 A
1 A
0.6 A
2 A
1 A
0.6 A
6 A
0.1 A
0.05 A
6 A
0.1 A
0.05 A
3 A
0.1 A
0.05 A
Parallel
connection
125 VAC
250 VAC
6 A
6 A
3 A
2.5 A
1.5 A
1.25 A
4 A
4 A
4 A
2 A
2 A
1 A
30 VDC
125 VDC
250 VDC
6 A
0.6 A
0.3 A
4 A
0.6 A
0.3 A
2 A
0.6 A
0.3 A
4 A
0.1 A
0.05 A
6 A
0.1 A
0.05 A
3 A
0.1 A
0.05 A