General-purpose Basic Switch Z F-165
Limit
Switches
Characteristics
Note: 1. The values are for the plunger models. (For the lever models, the values are at the plunger section.) (Contract your OMRON represen-
tative for other models.)
2. The values are for the Z-15G pin plunger.
3. The values are for the Z-10FY-B.
4. The values are for the pin plunger. The durability for models other than the pin plunger is 10,000,000 min.
5. Malfunction: 1 ms max.
Item Basic
(except micro load
and flexible rod)/
maintained
contact
Z-15
Basic
(micro load)
Z-01H
Basic
(flexible rod)
Z-15
Split-contact
Z-10F
Operating speed
(see note)
0.01 mm to 1 m/s (see note 1) 1 mm to 1 m/s 0.1 mm to 1 m/s (see note 1)
Operating frequency Mechanical: 240 operations/min
Electrical: 20 operations/min
Mechanical: 120 operations/min
Electrical: 20 operations/min
Mechanical: 240 operations/min
Electrical: 20 operations/min
Insulation resistance 100 M min. (at 500 VDC)
Contact resistance 15 m max. (initial
value)
50 m max. (initial
value)
15 m max. (initial value) 25 m max. (initial value)
Dielectric strength Between contacts of same polarity
Contact gap G: 1,000 VAC, 50/60 Hz for
1min
Contact gap H: 600 VAC, 50/60 Hz for
1min
Contact gap E: 1,500 VAC, 50/60 Hz for
1min
Between current-carrying metal parts and
ground, and between each terminal and
non-current-carrying metal parts
2,000 VAC, 50/60 Hz for 1 min
Between contacts of same polarity
Contact gap G: 1,000 VAC, 50/
60 Hz for 1 min
Contact gap H: 600 VAC, 50/ 60 Hz
for 1 min
Between current-carrying metal
parts and ground, and between each
terminal and non-current-carrying
metal parts
2,000 VAC, 50/60 Hz for 1 min
Between contacts of same polarity
Contact gap F: 1,500 VAC, 50/
60 Hz for 1 min
Between current-carrying metal
parts and ground, and between each
terminal and non-current-carrying
metal parts
2,000 VAC, 50/60 Hz for 1 min
Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm double
amplitude (see note 5)
Malfunction: 10 to 20 Hz, 1.5-mm
double amplitude (see note 5)
Malfunction: 10 to 55 Hz, 1.5-mm
double amplitude (see note 5)
Shock resistance
Destruction
: 1,000 m/s
2
{approx. 100G} max.
Malfunction
: 300 m/s
2
{approx. 30G} max.
(see note 2, 5)
Destruction
: 1,000 m/s
2
{approx.
100G} max.
Malfunction
:50 m/s
2
{approx. 5G} max.
(see note 5)
Destruction
: 1,000 m/s
2
{approx.
100G} max.
Malfunction
: 300 m/s
2
.
{approx. 30G} max.
(see note 3, 5)
Durability Mechanical
:
Contact gap G, H: 20,000,000 operations
min. (see note 4)
Contact gap E: 300,000 operations
Electrical
:
Contact gap G, H: 500,000 operations
min.
Contact gap E: 100,000 operations
min.
Mechanical
: 1,000,000 operations
min.
Electrical
: 100,000 operations
min.
Mechanical
: 500,000 operations
min. (see note 1)
Electrical
: 100,000 operations
min.
Degree of protection General-purpose: IP00
Drip-proof: IP62
Degree of protection
against electric shock
Class I
Proof tracking index
(PTI)
175
Switch category D (IEC335-1)
Ambient temperature Operating:
General-purpose: 25°C to 80°C (with no icing)
Drip-proof: 15°C to 80°C (with no icing)
Ambient humidity Operating:
General-purpose: 35% to 85%
Drip-proof: 35% to 95%
Weight Approx. 22 to 58 g Approx. 42 to 48 g Approx. 34 to 61 g