AIR CONDITIONERS
Warranty Registration System
Help us to serve you better by registering
your product for Warranty
Web Register at w
Telephone
Post / Visit Post the Warranty Registration Card &
ww.onida.com
Call Centre No. 0XX-39889000(0XX-STD Code of
State Capital)
Service Centre
Copy or Visit the Nearest Service Centre.
Collection Center address
Mirc Electronics Ltd.Village Kudus,Bhiwandi Wada road,
Taluka Wada., Dist. Thane - 421312,Tel no. 952525 220375/377
Visit at : for details about collection Centers. www.onida.com
As per Government of Indias E-Waste (Management and Handling)
Rules, 2011(effective from May 1st, 2012) the product purchased by you
is to be considered as E-Waste and cannot be disposed off with your
general household waste. It should be disposed of through the companys
collection center so as to prevent any damage to environment
We request you to make a note of the above details and support us
in our endeavour to ensure an environmental friendly nation.
3 STAR 2 STAR
Model:
S09FLT-L3/ S12FLT-L3/ S18FLT-L3/ S24FLT-L3
S09FLT-L4/ S12FLT-L4/ S18FLT-L4
Question and Answer IconNeed help?

Do you have a question about the Onida S09FLT-L3 and is the answer not in the manual?

Overview

This document is a user manual for ONIDA Air Conditioners, providing comprehensive information about the product's features, operation, installation, maintenance, and warranty.

Function Description:

The ONIDA Air Conditioner is designed to provide cooling and comfort in indoor environments. It offers various operating modes, including Auto, Cool, Dry, and Fan, to suit different user preferences and environmental conditions. The unit is equipped with a remote control for convenient operation and features such as a timer, sleep mode, and auto-restart. The air conditioner also incorporates energy-saving technologies and aims to deliver efficient performance.

Important Technical Specifications:

  • Models: S09FLT-L3/S12FLT-L3/S18FLT-L3/S24FLT-L3, S09FLT-L4/S12FLT-L4/S18FLT-L4.
  • Capacity: Available in 0.8T, 1.0T, and 1.5T Split Air Conditioner variants.
  • Energy Rating: 3 Star / 2 Star Energy Saver BEE Rated (depending on model).
  • Compressor: High BTU Tropicalised Compressor.
  • Condenser Coil: Large L-Shaped Condenser Coil.
  • Indoor Unit Design: Sleek Indoor Unit with a unique flat panel.
  • Refrigerant Pipe Dimensions (1.0 T): Liquid pipe 6.35 mm, Gas pipe 12.7 mm.
  • Refrigerant Pipe Dimensions (1.5 T): Liquid pipe 6.35 mm, Gas pipe 12.7 mm.
  • Torque (N·m) for Refrigerant Pipes (1.0 T): Liquid pipe 13.7–17.6, Gas pipe 49.0–56.4.
  • Torque (N·m) for Refrigerant Pipes (1.5 T): Liquid pipe 13.7–17.6, Gas pipe 49.0–56.4.
  • Recommended Operating Voltage: 230V +/- 10%.
  • Maximum Distance between IDU and ODU: 12 meters (when IDU and ODU are at the same level).
  • Maximum Height Difference between IDU and ODU: 5 meters.
  • Cooling Capacity Measurement: Measured at High speed, as per IS 1391:1992 Part 2.
  • Setting Temperature Range: 16-31°C.
  • Remote Control Range: Up to six meters from the indoor unit.

Usage Features:

  • Operating Modes: Auto, Cool, Dry, Fan, and Turbo modes.
  • i-Cool Function: For instant cooling.
  • Smart Sleep: Offers 4 personal preference modes for comfortable sleep.
  • Turbo-Cool Function: Provides rapid cooling in adverse conditions.
  • 3 Stage Filtration: For better air quality.
  • Auto-Restart: Automatically resumes operation after a power outage.
  • Full Function LCD Remote: Enables comprehensive control over the unit.
  • Temperature Adjustment: Allows users to increase or decrease the set temperature by 1°C increments.
  • Fan Speed Control: Multiple fan speed settings (Low, Med, High, Auto) to adjust airflow.
  • Timer Function: Allows setting ON/OFF times for scheduled operation.
  • Manual/Auto Swing: Controls the direction of airflow.
  • Money Saved Mode: (Not available with all models) An energy-saving feature.
  • Energy Saver Mode: Reduces energy consumption by running the compressor at a selectable fan speed.
  • i-Cool Ceiling Fan Controller: (Optional accessory, not included in all models) Provides additional control over the ceiling fan.
  • Air Flow Direction Adjustment: Manual adjustment of horizontal louvers and automatic adjustment of up/down louvers.
  • Emergency Operation Switch: For manual operation in case of remote control malfunction.

Maintenance Features:

  • Filter Cleaning: Users can easily lift the front panel, remove the filters, and wash them under a tap. It is recommended not to use detergents for cleaning the filter.
  • Professional Maintenance: Most maintenance work, especially during and after the warranty period, should be handled by a trained technician.
  • E-Waste Disposal: The product is considered E-Waste and should be disposed of through the company's collection center to prevent environmental damage, as per Government of India's E-Waste (Management and Handling) Rules, 2011.

Installation Guidelines:

  • Indoor Unit Placement: Should be located for optimal cool air circulation, away from obstructions and frequently opened doors. Condensate water must be drained properly, with a "U" bend in the drain tube to prevent insects.
  • Outdoor Unit Placement: Should be mounted on a strong frame or support, with adequate space for free airflow (at least 2 meters on the outlet side and 0.3 meters on the inlet side). It should not be too far from the indoor unit, with recommended distances provided. If multiple ODUs are installed, they must be properly separated.
  • Piping and Wiring: Avoid long, complicated routing and too many bends in the connection pipes and wires. Special cables are used for connecting indoor and outdoor units.
  • Electrical Outlet: A suitable electrical outlet must be provided near the indoor unit.
  • Vacuum Pump: Used to discharge air from the pipe assembly before adding refrigerant.
  • Refrigerant Addition: If the connecting pipe is longer than 7 meters, additional refrigerant may be needed.

Warranty and Support:

  • Warranty Period: 12 months for the air conditioner (excluding front grill, knobs, remote unit, and add-on plastic parts) and 60 months for the compressor from the date of invoice.
  • Warranty Registration: Users are encouraged to register their product online at www.onida.com or by post/visit to a service center.
  • Customer Service: Call Centre No. 0XX-39889000 (0XX-STD Code of State Capital) or email response@onida.com for feedback and suggestions.
  • Preventive Maintenance Service: Coupons for two preventive maintenance services are included in the manual.
  • Troubleshooting Chart: Provides common symptoms, possible causes, and suggested remedies for issues like the unit not starting or not cooling effectively.