ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL PORTUGUÊS
EN-1
PHOTOELECTRIC DETECTOR
PHOTOELECTRIC DETECTOR
CONTENTS
1 INTRODUCTION
1-1 BEFORE YOUR OPERATION ............................... 2
1-2 PRECAUTIONS...................................................... 3
2 PARTS IDENTIFICATION............................................ 3
3 INSTALLATION
3-1 NOTE...................................................................... 4
3-2 INSTALLATION METHOD .................................... 4
4 WIRE CONNECTION................................................... 6
5 ALIGNMENT
5-1 OPTICAL ALIGNMENT .......................................... 7
5-2 BEAM INTERRUPTION TIME................................ 8
5-3 SELECTABLE BEAM FREQUENCIES
< AX-100/200TF ONLY >....................................... 8
6 WALK TEST................................................................. 9
7 SPECIAL FUNCTION < AX-100/200TF ONLY >
7-1 ENVIRONMENTAL DISQUALIFICATION.............. 9
7-2 ALARM MEMORY.................................................. 9
8 OPTIONAL ACCESSORIES
8-1 HEATING UNIT : HU-3......................................... 10
8-2 BACK COVER : BC-3........................................... 11
8-3 POLE SIDE COVER : PSC-3 ............................... 11
9 TROUBLESHOOTING............................................... 12
10
SPECIFICATIONS
10-1 SPECIFICATIONS.............................................. 13
10-2 DIMENSIONS & OPTION................................... 14
INSTALLATION INSTRUCTIONS
FEATURES
No.59-2419-1 1701-31
No.59-1282-7 0904-30
AX-70TN, AX-130TN, AX-200TN
AX-100TF, AX-200TF
< AX-70/130/200TN, AX-100/200TF >
•High-performance waterproof structure
•Horizontal alignment dial for user-friendliness
•Adjustable beam interruption period
•Tamper function
Optional Accessories : Heating unit (HU-3), Back cover (BC-3),
Pole side cover (PSC-3)
•UL Listed
< AX-100/200TF ONLY >
•4 selectable beam frequencies
•LED indicator for fine beam alignment level
•D.Q. circuit (Environmental disqualification)
•Alarm memory
AX-200TN 60 m / 200 ft.
30 m / 100 ft.
4 selectable beam
frequencies
60 m / 200 ft.
AX-100TF
AX-200TF
Model Detection range Feature
20 m / 70 ft.
40 m / 130 ft.
Standard model with
detection range
60 m / 200 ft.
AX-70TN
AX-130TN
UL
AX-70TN, AX-130TN, AX-200TN
AX-100TF, AX-200TF

Other manuals for Optex AX-200TF

Questions and Answers

  • T
    Terry WilliamsAug 7, 2025
    Why is the 'Alarm Indicator' not illuminated when the beam is blocked on my Optex AX-200TF?
    • O
      ostuartAug 7, 2025
      The 'Alarm Indicator' might not illuminate on your Optex Security Sensors due to several reasons: the power supply voltage may be inappropriate (check that the voltage is between 10.5 and 28VDC); the wiring distance or wire diameter may be inappropriate (check the wiring distance); beams may be reflecting off surfaces and entering the receiver (realign the optical axis, remove reflecting objects, or change the installation site); you might not be interrupting both upper and lower beams simultaneously (interrupt both beams at the same time); or the receiver may be picking up beams from other transmitters (move the receiver to a location free from other transmitters' beams).
  • K
    keithholtAug 12, 2025
    How to fix Optex AX-200TF alarm activating even if the light is not blocked?
    • B
      Becky CopelandAug 12, 2025
      If your Optex Security Sensors alarm activates without the light being blocked, consider these potential causes: * An object might be intermittently blocking the beam (remove any obstructions). * A vehicle or plant may be interfering (relocate the sensors). * The transmitter/receiver cover could be dirty (clean it with a soft, damp cloth). * The optical alignment might be inaccurate (realign the sensors). * The installation location may be inappropriate (change the location).
  • T
    Tara CollierAug 16, 2025
    How to fix Optex Security Sensors LEDs on the transmitter not illuminated?
    • N
      nathanhallAug 16, 2025
      If the LEDs on the transmitter of your Optex Security Sensors are not illuminated, it could be due to: inappropriate power supply voltage (ensure it's between 10.5 and 28VDC), a disconnection in the power line (check the wiring), or inappropriate wiring distance or wire diameter (check the wiring distance).
  • S
    Sophia RoseAug 22, 2025
    What to do if blocking the beam doesn't activate the alarm on Optex Security Sensors?
    • E
      eric69Aug 22, 2025
      If blocking the beam in front of the receiver illuminates the 'Alarm Indicator' but doesn't activate the alarm on your Optex Security Sensors, the signal line may be short-circuited (check the wiring) or the alarm contact may be welded (repair is required, contact the distributor or installer).
  • J
    Jessica JohnsonAug 27, 2025
    Why doesn't the 'Alarm Indicator' of the Optex AX-200TF receiver go out?
    • A
      Andrew RojasAug 27, 2025
      If the 'Alarm Indicator' on your Optex Security Sensors receiver remains illuminated, it could be because the optical axis of the transmitter and receiver are not aligned (make realignment) or an object is blocking the beam between them (remove the object or move the unit).
  • A
    Adrienne HamiltonAug 31, 2025
    Why frost, snow, or heavy rain cause false alarms in Optex AX-200TF Security Sensors?
    • A
      Alicia HodgeAug 31, 2025
      Frost, snow, or heavy rain can cause false alarms in Optex Security Sensors if the optical alignment is not optimized. Make realignment.

Summary

Introduction

Before Your Operation

Provides instructions and warnings for safe product use and handling.

Installation

Installation Method

Describes detaching the cover and fixing the mounting plate for installation.

Alignment

Optical Alignment

Explains rough alignment using a viewfinder and fine adjustment with a monitor jack.

Walk Test

Troubleshooting

LEDs on the Transmitter Are Not Illuminated

Troubleshooting steps for non-illuminated transmitter LEDs.

Alarm Indicator Is Not Illuminated Even If the Beam Is Blocked

Steps to resolve issues with the alarm indicator not illuminating when the beam is blocked.

Specifications

Specifications

Details the technical specifications for different detector models and accessories.

Optex AX-200TF Specifications

General IconGeneral
Product colorBlack
Transmission range60 - 600 m
Ambient temperature (min)-35 °C
Output voltage10.5 - 28 V
Maximum current0.2 A
Weight and Dimensions IconWeight and Dimensions
Weight700 g

Related product manuals