DO NOT DISCARD - GIVE THIS MANUAL TO THE OWNER AFTER INSTALLATION
● Installation must conform to all local plumbing codes and regulations.
● Do NOT use with water that is microbiologically unsafe or of unknown quality without adequate
d
isinfection before or after the system. Systems certified for cyst reduction may be used on
d
isinfected waters that may contain filterable cysts.
● Connect system to cold water supply only! Water temperature must not exceed 100°F/38°C.
● Do NOT solder plumbing connections attached to the assembly. High temperature will damage
these components.
● Do NOT over-tighten fitting connections. Always back-up valves and fittings with a wrench to
avoid turning the valve.
● Allow a minimum of 3” under the housing to allow for sump removal and filter replacement.
● Do NOT mount the system near a heat source or above the electrical wiring or any device or
area that would be adversely affected by water.
● Do NOT mount the system behind equipment. The unit must be easily accessible for filter
replacement.
● Failure to change cartridges per recommended intervals with OptiPure replacement cartridges
may lead to system failure and property damage.