User Guide
Optos Panoramic Ophthalmoscope
P200DTx rg
P200DTx rgb
P200DTx fa
P200DTx icg
G108025-010-ENG

Table of Contents

Questions and Answers

  • S
    Sarah BlackburnAug 5, 2025
    What to do if I cannot access the user login list on the Optos Medical Equipment scan head?
    • R
      Richard BrownAug 5, 2025
      If you cannot access the user login list, check your username and password. Also, verify that the image server is switched on and running. Finally, confirm the image server network address and ensure the scan head is on the same network and configured to connect to the correct address. The issue might be a password error, the image server not being switched on, or the scan head not configured with the correct image server IP address.
  • H
    hernandezloriAug 10, 2025
    What to do if I cannot align the patient with the hand control in Optos California P200DTx rg?
    • M
      Marie AtkinsAug 10, 2025
      Ensure the patient’s pupil is centered on the cross hairs on the touch screen. The cause may be equipment failure or the device setup being incorrect.
  • J
    Jillian AcevedoAug 15, 2025
    Why is patient position feedback NOT showing on some eyes with Optos Medical Equipment?
    • M
      Michelle ChandlerAug 15, 2025
      Ensure the patient’s pupil is centered on the cross hairs on the touch screen. This issue can arise due to ambient lighting being too bright, irregular pupil shape, or unmanaged ptosis.
  • B
    Brian CookAug 20, 2025
    What to do if imaging when the patient position feedback is green does NOT produce good results with Optos California P200DTx rg?
    • J
      Jennifer BennettAug 20, 2025
      If imaging with green patient position feedback doesn't yield good results, compensate by imaging with the alignment target on red or blue, as appropriate. This is because the system virtual point might be offset, leading to incorrect feedback.
  • A
    Amanda OlsenAug 25, 2025
    Why Optos Medical Equipment images include large lid and lash obscuration?
    • R
      robin93Aug 26, 2025
      The issue of images including large lid and lash obscuration is often due to poor patient position or unmanaged ptosis. Review the positioning guidance in this document.
  • G
    gcruzAug 29, 2025
    How to fix disabled capture mode on Optos Medical Equipment?
    • J
      James MedinaAug 29, 2025
      If the capture mode is disabled, open the diagnostics page and run the self-test feature. This is often due to the failure of the system self-test.

Summary

Warnings and Cautions

General Safety

General safety guidelines for operating the Optos P200DTx system, including patient considerations.

Laser Safety

Safety precautions and hazards associated with laser use in the Optos P200DTx.

Electrical Safety

Electrical safety precautions for operating the Optos P200DTx system.

Environmental Safety

Environmental considerations and safety guidelines for the Optos P200DTx.

EMC Safety

Electromagnetic Compatibility (EMC) guidelines and precautions for the Optos P200DTx.

Device Failure

Instructions for handling device failures and basic troubleshooting steps.

Cleaning Guidelines

Guidelines for cleaning the Optos P200DTx device, including patient contact parts.

Information Security

Procedures for maintaining information security and IT network safety.

Data Security

Guidelines and responsibilities for ensuring data security and patient privacy.

Software Management

Instructions for installing and updating software on Optos-supplied PCs.

Symbols and Labels

Explanation of symbols and labels used on the Optos P200DTx device.

Introduction

Device Overview

Overview of the Optos P200DTx device, its features, and capabilities.

Product Information

Clinical benefits, intended use, users, environment, contraindications.

System Configuration

Components, network specs, image modalities, software, and accessories.

Get Started

Daily Power Management

Daily procedures for powering on the image server/scan head and shutting down the system.

System Controls and Operation

Operating the Optos P200DTx using touch screen, keyboard, and hand control.

Capture Images

Patient Record Management

Selecting, adding, editing patient details, and using Modality Work List (MWL).

Preparation and Alignment

Preparing the system and aligning the patient for optimal image capture.

Image Modalities

Capturing SLO, eye-steered, stereo, and angiography images.

Multi-mode Workflow

Using Multi-mode for capture and managing the patient session.

Review Images

Accessing the Review Software

Steps to launch and log into the OptosAdvance review application.

Reviewing Captured Images

Navigating and analyzing patient images and scans within OptosAdvance.

Exiting the Review Software

Proper procedure for closing the OptosAdvance review application.

Manage the System

User Account Management

Creating and managing user accounts on the scan head and image server.

Language and Data Management

Changing language settings and managing image storage/archiving.

Network and MWL Management

Managing system connections and the Modality Work List (MWL).

System Quality Checks

Performing self-tests, checking status indicators, and managing software updates.

Maintenance and Cleaning

Servicing and Warranty

Information on professional servicing and the product warranty.

Cleaning Procedures

Detailed procedures for cleaning the Optos P200DTx, including daily, pre-patient, and mirror cleaning.

Battery and Cable Management

Handling battery replacement and proper cable management for the system.

Troubleshooting

Login and Connection Issues

Resolving login failures, password errors, and network connection problems.

Alignment and Imaging Problems

Troubleshooting alignment recognition and imaging issues.

System Restart Procedures

How to restart the scan head and image server to resolve common system issues.

Storage Capacity Issues

Addressing issues when the image server's PC drive becomes full.

Technical Specification

Safety and System Specifications

Safety designations, system components, dimensions, and environmental parameters.

Laser Safety

Laser safety classification, warnings, and emission details.

Electromagnetic Compatibility (EMC)

EMC declarations, immunity guidelines, and separation distances.

Contact Us

Global Headquarters

Contact details for Optos plc's main global headquarters.

Regional Office Contacts

Contact information for Optos regional offices worldwide.

Authorized Representatives

Contact information for the European and Swiss authorized representatives.

Optos California P200DTx rg Specifications