EasyManua.ls Logo

Oreck Vacuum Cleaners - Replacing Edge Brush; Replacing LED Light; Clearing Stuffing or Blockage

Oreck Vacuum Cleaners
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH
Replacing Edge Brush
WARNING: Unplug cord from electrical outlet before servicing.
Turnthepowerheadover.Withbaseplatefacingup,removethescrewlocatedinthecenterofeachedgebrush.
Removebothedgebrushesandreplacewithnewones.Replacebothscrewsandtighten.
Replacing the LED Light
ThelightassemblyshouldbereplacedbyanOreckauthorizedservicecenterwheneveritfailstolightduringoperation.
Stuffing or Blockage
IMPORTANT:Onplushandnewcarpets,stuffingmayoccurinsidetheintaketubeandthelowertubeassembly.Thisisduetoexcessivefuzz
andloosecuttingsinthecarpet.Stuffingcouldoccurforthefirstfewcleaningsuntilalltheloosematerialisremoved.Duetothehighefficiency
ofthecleaner,manyoldercarpetswillcausestuffingwhenthecleanerisfirstusedonthem.Ifyourvacuumcleanerdoesnotpickupproperly,or
makes unusual noise and the outer bag does not fluff up or balloon open, follow these steps:
WARNING: Unplug cord from electrical outlet before servicing.
Checkforblockageatthemouthoftheintakeopening.Ifthereisblockage,removeitwithlong-nosepliers,
ascrewdriverorcoathanger.Ifyoucannotreachtheblockage,removebaseplate.Removethebaseplatebyremoving5screws
(see “Replacing Brushroll”).
Iftheblockageisnotatthebase,removelowertube.Unhookbagspring,releasingbottomofbag.
Twistlowercollarcounterclockwisetoslideup.Pulltubeoutofbase.Checkforblockage.Ifblockageisinthetube,removewithacoathanger.
Iftubeisnotblocked,lookintofanhousing.Removedebriswithlong-nosepliers,ascrewdriverorcoathanger.
To reassemble, check O-ring on tube, and replace if damaged. Replace tube by first lining up slot at base of tube with tab inside fan housing.
Insert tube and push down until the tube is seated. Make sure O-ring is in place against fan housing opening. Replace and tighten collar until
collar locking tabs are locked in place. Reattach bag spring.
Many times blockage occurs due to a full HEPA Inner bag causing dirt to back down the air flow system. When that
happens, the blockage will be at the top of the system, starting in the area where the HEPA Inner bag connects to the connector assembly.
Note:Iftheaboveactionsdonotcorrecttheproblem,contactanOreckauthorizedservicecenterorcallthe
customerservicecenter.US: 1-800-989-3535 Canada: 1-888-676-7325
23
29
24
25
26
27
28
23
24 25 25 28 29
22
26 27
7
22

Table of Contents

Related product manuals