7 Operation
39
Timing chart
Two-step speed selection,
deceleration stop
High
speed
Low
speed
Run,
Instantaneous stop
Direction of rotation
selection
CW
(Clockwise direction)
CCW
(Counterclockwise
direction)
ON
OFF
Motor operating
pattern
START/
STOP input
CW/
CCW input
RUN/
BRAKE input
INT.VR/
EXT input
START
START
CW
CCW
RUN
RUN
RUN
EXT EXT
EXT
INT.VR
INT.VR
CW
∗1
∗1
∗1
∗1
∗1
∗1
∗1
∗1
∗1
∗1
∗1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
SPEED output
∗3
∗3
∗3
∗3
∗3
∗3
∗3
∗2
∗2
∗1
∗1 10 ms or more
∗2 The direction of rotation is the case of the motor alone. It depends on the gear ratio.
∗3 The motor starts and stops over the time set by the acceleration/deceleration time
potentiometer.