WARNING
WARNING
-4- -5-
01. Cautions
▶
Cautions for System installation
▶
Environmental condition for installation
- Since product panel is very sensitive for physical impact, installation requires considerable
caution.
- Minimum clearance(20cm) must be secured for smooth ventilation. (See page 6p~7p
참조
), nstallation must avoid air tight or near air tight places. Improper ventilation causes
malfunction and shortens product lifetime by rapid internal temperature rise. If product
has to installed at the improper ventilation, additional ventilation openings or fans must be
provided to keep the internal temperature between 0 ~ 35˚C.
- For ground of product and application devices, it should be connected as frame ground.
- Considering product Max power consumption, check the main electric specication.
▶
Recommended Operating Condition
- Temperature: 5~35˚C, Humidity: 35~75%, Suitable operating time : under 12 hours a day.
- Do not install the set at the air-tight condition.
- It is recommended to install the set with good ventilation.
- Do not install the set at the place of direct sunlight or excessive exposure to lightings.
※
Blackening, stains or burning effect on the screen can be occurred by improper installation
or use against the above recommended conditions.
▶
Consideration for easier service
- When you design the exterior design for product system, consider easier disassembly for
possible service occasion in the future.
- The sliding Universal Unit of ORION is recommended for easier service.
- If service people can step into the backside of product system, it can greatly reduce time and
effort for service.
- In case of higher locations, consider the installation location and exterior design for easier
service.
▶
Application information
If static images are displayed on the screen for a long time, it causes burn-in image.
Please keep the following instruction to optimize the lifetime and functions of the
product.
1. Operating condition
-
Temperature: 20
±
15˚C
-
Humidity: 55
±
20 %
-
Display pattern: moving picture or regular switchover display
-
Environmental condition : Well ventilated place is recommended.
-
Power off and screen saver : Periodical power-off or screen saver is needed after long-term static display.
※
Note : Moving picture or black pattern is strongly recommended for screen saver.
2. Operating methods to minimize burn-in image due to long-term static information
display
-
Suitable operating time : under 12 hours a day.
-
Periodical display contents change from static image to moving picture.
-
Periodical background color and character (image) color change
DEPARTURE
ÅÆ
DEPARTURE
Flight No. Time Gate Flight No. Time Gate
UA 012 11:20 A02 UA 012 11:20 A02
KE 732 12:10 K17 KE 732 12:10 K17
AN 291 12:45 F11 AN 291 12:45 F11
-
Change the images of little luminance difference between the background and characters, periodically.
DEPARTURE
Æ
DEPARTURE
Æ
DEPARTURE
Æ
DEPARTURE
Flight No. Time Gate Flight No. Time Gate Flight No. Time Gate Flight No. Time Gate
UA 012 11:20 A02 UA 012 11:20 A02 UA 012 11:20 A02 UA 012 11:20 A02
-
It is not recommended to display the images of huge luminance difference between the background and
characters or the images of grey tone.
ARRIVAL
(X)
ARRIVAL
(X)
Flight No. Time Gate Delay Flight No. Time Embark Delay
AA 213 9:20 K11 On time AA 213 9:20 New York On time
OZ 621 11:25 G21 10 min. OZ 621 11:25 Seoul 10 min.
JA 032 12:05 A19 On time JA 032 12:05 Beijing On time
-
Scroll the characters periodically.
DEPARTURE
Æ Æ
DEPARTURE
Flight No. Time Gate Flight No. Time Gate
UA 012 11:20 A02 UA 012 11:20 A02
KE 732 12:10 K17 KE 732 12:10 K17
AN 291 12:45 F11 AN 291 12:45 F11
(Whole Screen Scroll)