35
Cleaning and Appearance Care
Troubleshooting Guide
Make sure the battery is fully charged or replaced before performing any
trouble shooting ONLY to be performed by an adult.
PROBLEM POSSIBLE CAUSE SOLUTION
Power switch does not work or
light flickers when pushing the
sw
Faulty sw or bad connection
Battery not fully charged
Power switch is not good.
Replace the sw or throttle
Verify the battery is fully charged
Wire harness connection, faulty
switch, bad controller
Follow the throttle wire down
until it enters the frame, remove
the rubber plug and carefully pull
on the wire until the connector
comes out. Unplug the connector
and see if the wires have
corrosion, clean the pins and
reconnect.
Remove the controller box cover
and locate the solid dark blue
and black wires. Un-plug it and
pluck it back in, press the switch
– same result…
Unplug the connector and
connect a voltmeter (ohm
function) to red and blue wires
that go to the
switch and depress the switch.
You should see the meter go to 0.
No charge-switch is bad. If the
meter went to 0 then you have a
Stopped working while riding it Loose battery or
wire
Recharge or replace battery
Power switch faulty Contact your local ORION RXB-E
authorized service center for
diagnosis and repair
Throttle faulty
Motor or electrical system damage
Rider weight/ Terrain too steep Do not exceed the weight limit of
120lb (65kg), ride on flat terrain
Short run time/runs slow Battery not fully charged Verify the battery is fully charged
Old or damaged battery Replace battery